The reliability of quantifying upright standing postures as a baseline diagnostic clinical tool

被引:59
作者
Dunk, NM
Chung, YY
Compton, DS
Callaghan, JP [1 ]
机构
[1] Univ Guelph, Coll Biol Sci, Dept Human Biol & Nutr Sci, Guelph, ON N1G 2W1, Canada
[2] Univ Waterloo, Dept Kinesiol, Fac Appl Hlth Sci, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
spine; posture; reliability; precision; repeatability;
D O I
10.1016/j.jmpt.2003.12.003
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objective: To assess the reliability of posture across and within subjects, specifically the repeatability of spinal angles determined by digitization of images in the anterior, posterior, and sagittal views. Design: A repeated measure design was used in which subjects were required to attend 3 sessions, each consisting of 3 trials. Photographs of the anterior, posterior, and lateral views of normal, relaxed upright standing were taken during each trial. Landmarks were digitized and cervical, thoracic, and lumbar angles were calculated with respect to a vertical reference line. Subjects: Fourteen healthy and active subjects (7 male subjects and 7 female subjects) were recruited from a university student population. All had been free of low back pain during the previous 6 months. Results: When comparing mean angles, no significant differences were detected for any angle in any view. However, large variability within subjects was observed, likely leading to the lack of significance found with respect to the main factors in the analysis of variance (ANOVA). Large coefficients of variance (CVs) reflect the substantial intrasubject variability, as well as poor to moderate agreement indicated by intraclass correlation coefficients (ICCs). There were no apparent trends indicating that gender affected repeatability of posture. Conclusions: The poor repeatability of postures documented using the studied method brings into question the validity of this postural analysis approach for either diagnostic use or tracking changes in response to treatment. Users of such postural analysis tools should interpret postural deviations from a vertical reference with caution, as there are many inherent factors that can contribute to the variability of these measured postures.
引用
收藏
页码:91 / 96
页数:6
相关论文
共 13 条
[1]
Bullock-Saxton J, 1993, Aust J Physiother, V39, P25, DOI 10.1016/S0004-9514(14)60466-9
[2]
MEASUREMENT OF SCOLIOSIS AND KYPHOSIS RADIOGRAPHS - INTRAOBSERVER AND INTEROBSERVER VARIATION [J].
CARMAN, DL ;
BROWNE, RH ;
BIRCH, JG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) :328-333
[3]
Lumbar lordosis measurement: A new method versus Cobb technique [J].
Chernukha, KV ;
Daffner, RH ;
Reigel, DH .
SPINE, 1998, 23 (01) :74-79
[4]
Preliminary study of the reliability of assessment procedures for indications for chiropractic adjustments of the lumbar spine [J].
Hawk, C ;
Phongphua, C ;
Bleecker, J ;
Swank, L ;
Lopez, D ;
Rubley, T .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 1999, 22 (06) :382-389
[5]
LOVELL FW, 1989, PHYS THER, V69, P96, DOI 10.1093/ptj/69.2.96
[6]
MEASUREMENT OF THE TRUNK MUSCULATURE OF ACTIVE MALES USING CT SCAN RADIOGRAPHY - IMPLICATIONS FOR FORCE AND MOMENT GENERATING CAPACITY ABOUT THE L4/L5 JOINT [J].
MCGILL, SM ;
PATT, N ;
NORMAN, RW .
JOURNAL OF BIOMECHANICS, 1988, 21 (04) :329-&
[7]
MEASUREMENT OF THE COBB ANGLE ON RADIOGRAPHS OF PATIENTS WHO HAVE SCOLIOSIS - EVALUATION OF INTRINSIC ERROR [J].
MORRISSY, RT ;
GOLDSMITH, GS ;
HALL, EC ;
KEHL, D ;
COWIE, GH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) :320-327
[8]
Measurement of lumbar lordosis - Evaluation of intraobserver, interobserver, and technique variability [J].
Polly, DW ;
Kilkelly, FX ;
McHale, KA ;
Asplund, LM ;
Mulligan, M ;
Chang, AS .
SPINE, 1996, 21 (13) :1530-1535
[9]
INTRACLASS CORRELATIONS - USES IN ASSESSING RATER RELIABILITY [J].
SHROUT, PE ;
FLEISS, JL .
PSYCHOLOGICAL BULLETIN, 1979, 86 (02) :420-428
[10]
Inter- and intra-observer reliability of calculating cumulative lumbar spine loads [J].
Sullivan, D ;
Bryden, P ;
Callaghan, JP .
ERGONOMICS, 2002, 45 (11) :788-797