Assessment of air quality in Turin by personal monitoring of nonsmokers for respirable suspended particles and environmental tobacco smoke

被引:24
作者
Phillips, K
Howard, DA
Bentley, MC
Alvan, G
机构
[1] Dept. of Environmental Air Quality, Covance Laboratories Ltd., Harrogate
[2] Division of Clinical Pharmacology, Karolinska Institute, Huddinge University Hospital, Huddinge
关键词
D O I
10.1016/S0160-4120(97)00097-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Exposure to respirable suspended particles (RSP), environmental tobacco smoke (ETS) particles, nicotine, and 3-ethenylpyridine (3-EP) was assessed in Turin for 188 subjects during February and March 1995. Personal monitors were worn over a 24-h period, each subject providing a saliva sample for cotinine analysis both prior to and following the monitoring period, Comprehensive lifestyle questionnaires were also completed before and after the 24-h monitoring period. The study comprised housewives in one group, primarily for assessing exposures in the home, and office workers in a second group to assess exposures in the workplace. A single personal monitor was worn by each participating housewife, while employed subjects wore one monitor at work and a separate monitor at home and elsewhere, Based on median 24-h time-weighted average exposures, the most highly exposed subjects to RSP, ETS particles, nicotine, and 3-EP were office workers living with smokers and employed in locations where smoking was allowed. Annualised exposures for nonsmokers living and working in smoking environments indicate that the home contribution to RSP is between 3 and 4 times that obtained from the workplace. Similarly nicotine and ETS particle contributions from the home are, respectively, 4 and 7 times more than those obtained from the workplace, Subjects living and working with smokers had the highest median saliva cotinine levels of 1.7 ng mL(-1). Using a cut off level of 25 ng mL(-1), up to 6.5% of subjects were found to have misreported themselves as nonsmokers. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:851 / 871
页数:21
相关论文
共 20 条
[1]   Indoor air quality in homes, offices and restaurants in Korean urban areas - Indoor/outdoor relationships [J].
Baek, SO ;
Kim, YS ;
Perry, R .
ATMOSPHERIC ENVIRONMENT, 1997, 31 (04) :529-544
[2]  
DELFINO RJ, 1993, EUR RESPIR J, V6, P1104
[3]  
EATOUGH DJ, 1993, AM SOC TEST MATER, V1205, P42, DOI 10.1520/STP13099S
[4]   A REVIEW OF THE USE OF SALIVA COTININE AS A MARKER OF TOBACCO-SMOKE EXPOSURE [J].
ETZEL, RA .
PREVENTIVE MEDICINE, 1990, 19 (02) :190-197
[5]   INDOOR AIR-QUALITY AND ENVIRONMENTAL TOBACCO-SMOKE - CONCENTRATION AND EXPOSURE [J].
HOLCOMB, LC .
ENVIRONMENT INTERNATIONAL, 1993, 19 (01) :9-40
[6]  
Jenkins RA, 1996, J EXPO ANAL ENV EPID, V6, P473
[8]  
MCNEILL AD, 1987, BRIT J ADDICT, V82, P1355
[9]   Composition of environmental tobacco smoke (ETS) from international cigarettes and determination of ETS-RSP: Particulate marker ratios [J].
Nelson, PR ;
Conrad, FW ;
Kelly, SP ;
Maiolo, KC ;
Richardson, JD ;
Ogden, MW .
ENVIRONMENT INTERNATIONAL, 1997, 23 (01) :47-52
[10]  
NELSON PR, 1990, MEASUREMENT TOXIC RE, P550