Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer -: art. no. 18

被引:66
作者
de Winter, AF
Heemskerk, MAMB
Terwee, CB
Jans, MP
Devillé, W
van Schaardenburg, DJ
Scholten, RJPM
Bouter, LM
机构
[1] Vrije Univ Amsterdam Med Ctr, Inst Res Extramural Med, NL-1081 BT Amsterdam, Netherlands
[2] Univ Groningen, Univ Groningen Hosp, Dept Soc Psychiat, NL-9700 RB Groningen, Netherlands
[3] Dutch Natl Inst Allied Hlth Profess, NL-3800 BD Amersfoort, Netherlands
[4] TNO Work & Employment, NL-2130 AS Hoofddorp, Netherlands
[5] Netherlands Inst Hlth Serv Res NIVEL, NL-3500 BN Utrecht, Netherlands
[6] Vrije Univ Amsterdam Med Ctr, Dept Rheumatol, NL-1007 MB Amsterdam, Netherlands
[7] Dutch Cochrane Ctr, NL-1100 DD Amsterdam, Netherlands
关键词
D O I
10.1186/1471-2474-5-18
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Reproducible measurements of the range of motion are an important prerequisite for the interpretation of study results. The digital inclinometer is considered to be a useful instrument because it is inexpensive and easy to use. No previous study assessed inter-observer reproducibility of range of motion measurements with a digital inclinometer by physical therapists in a large sample of patients. Methods: Two physical therapists independently measured the passive range of motion of the glenohumeral abduction and the external rotation in 155 patients with shoulder pain. Agreement was quantified by calculation of the mean differences between the observers and the standard deviation (SD) of this difference and the limits of agreement, defined as the mean difference +/- 1.96*SD of this difference. Reliability was quantified by means of the intraclass correlation coefficient (ICC). Results: The limits of agreement were 0.8 +/- 19.6 for glenohumeral abduction and -4.6 +/- 18.8 for external rotation (affected side) and quite similar for the contralateral side and the differences between sides. The percentage agreement within 10 for these measurements were 72% and 70% respectively. The ICC ranged from 0.28 to 0.90 (0.83 and 0.90 for the affected side). Conclusions: The inter-observer agreement was found to be poor. If individual patients are assessed by two different observers, differences in range of motion of less than 20-25 degrees can not be distuinguished from measurement error. In contrast, acceptable reliability was found for the inclinometric measurements of the affected side and the differences between the sides, indicating that the inclimeter can be used in studies in which groups are compared.
引用
收藏
页数:8
相关论文
共 30 条
[1]  
Aaronson N, 2002, QUAL LIFE RES, V11, P193
[2]   Measuring shoulder internal rotation range of motion: A comparison of 3 techniques [J].
Awan, R ;
Smith, J ;
Boon, AJ .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (09) :1229-1234
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   RELIABILITY OF GONIOMETRIC MEASUREMENTS [J].
BOONE, DC ;
AZEN, SP ;
LIN, CM ;
SPENCE, C ;
BARON, C ;
LEE, L .
PHYSICAL THERAPY, 1978, 58 (11) :1355-1360
[5]   CLINICAL RELIABILITY OF SHOULDER FUNCTION ASSESSMENT IN PATIENTS WITH RHEUMATOID-ARTHRITIS [J].
BOSTROM, C ;
HARMSRINGDAHL, K ;
NORDEMAR, R .
SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 1991, 20 (01) :36-48
[6]  
CHIARELLO CM, 1993, ARCH PHYS MED REHAB, V74, P32
[7]  
CROFT P, 1994, BRIT J RHEUMATOL, V33, P942
[8]   Diagnostic classification of shoulder disorders:: interobserver agreement and determinants of disagreement [J].
de Winter, AF ;
Jans, MP ;
Scholten, RJPM ;
Devillé, W ;
van Schaardenburg, D ;
Bouter, LM .
ANNALS OF THE RHEUMATIC DISEASES, 1999, 58 (05) :272-277
[9]  
DEVET HCW, 1998, ENCY BIOSTATISTICA, V4, P3123
[10]  
Fleiss JL, 1986, The Design and Analysis of Clinical Experiments