Determination of peroxide value by Fourier transform near-infrared spectroscopy

被引:81
作者
Li, H
van de Voort, FR
Ismail, AA
Cox, R
机构
[1] McGill Univ, Dept Food Sci & Agr Chem, McGill IR Grp, St Anne De Bellevue, PQ H9X 3V9, Canada
[2] Bomem Inc, Quebec City, PQ G2E 5S5, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Fourier transform infrared spectroscopy; FT-IR; FT-NIR; oil analysis; peroxide value;
D O I
10.1007/s11746-000-0023-7
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A Fourier transform-near infrared (FT-NIR) method originally designed to determine the peroxide value (PV) of triacylglycerols at levels of 10-100 PV was improved upon to allow for the analysis of PV between 0 and 10 PV, a range of interest to the edible oil industry. The FT-NIR method uses convenient disposable glass vials for sample handling, and PV is determined by spectroscopically measuring the conversion of triphenylphosphine (TPP) to triphenylphosphine oxide (TPPO) when reacted with hydroperoxides. A partial-least-squares calibration was developed for 8 mm o.d. vials by preparing randomized mixtures of TPP and TPPO in a zero-PV oil. The method was validated with samples prepared by gravimetric dilution of oxidized oil with a zero-PV oil. It was shown that the American Oil Chemists' Society primary reference method was quite reproducible (+/-0.5 PV), but relatively insensitive to PV differences at lower (0-2) PV. The FT-NIR method on the other hand was shown to be more accurate overall in tracking PV, but slightly less reproducible (0.9 PV) due to working close to the limit of detection. The sensitivity and reproducibility of the FT-NIR method could be improved upon through the use of larger-diameter vials combined with a detector having a wider dynamic range. The proposed FT-NIR PV method is simple to calibrate and implement and can be automated to allow for routine quality control analysis of edible fats and oils.
引用
收藏
页码:137 / 142
页数:6
相关论文
共 8 条
[1]  
*AM OIL CHEM SOC, 1989, OFF METH REC PRACT A
[2]  
Dong J, 1997, J AOAC INT, V80, P345
[3]   Stoichiometric determination of hydroperoxides in fats and oils by Fourier transform infrared spectroscopy [J].
Ma, K ;
vandeVoort, FR ;
Sedman, J ;
Ismail, AA .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1997, 74 (08) :897-906
[4]  
Ma K, 1998, J AM OIL CHEM SOC, V75, P1095, DOI 10.1007/s11746-998-0119-3
[5]  
vandeVoort FR, 1996, LAB ROBOTICS AUTOMAT, V8, P205, DOI 10.1002/(SICI)1098-2728(1996)8:4<205::AID-LRA2>3.0.CO
[6]  
2-4
[7]   THE DETERMINATION OF PEROXIDE VALUE BY FOURIER-TRANSFORM INFRARED-SPECTROSCOPY [J].
VANDEVOORT, FR ;
ISMAIL, AA ;
SEDMAN, J ;
DUBOIS, J ;
NICODEMO, T .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1994, 71 (09) :921-926
[8]  
VANDEVOORT FR, 1994, INFORM, V5, P1038