Reversed-phase ion-interaction chromatography of Cu(I)-cyanide complexes

被引:10
作者
Fagan, PA [1 ]
Haddad, PR [1 ]
机构
[1] UNIV TASMANIA,DEPT CHEM,HOBART,TAS 7001,AUSTRALIA
关键词
complex dissociation; metal complexes; cyanide complexes; copper complexes;
D O I
10.1016/S0021-9673(96)01086-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
It has been established that during the separation of Cu(I)-cyanide complexes, the cyanide:Cu(I) molar ratio, R, of the eluted complex remained constant irrespective of the R value injected onto the column, and there was considerable tailing of the unretained cyanide peak and fronting of the Cu(I)-cyanide peak in an eluent containing no cyanide. The addition of small amounts of cyanide (100 mu M) to the eluent resulted in the elimination of these effects on peak shape and a significant increase in the retention of the Cu(I)-cyanide species. These results suggested that more than one Cu(I)-cyanide complex may be present in the Cu(I)-cyanide peak in an eluent containing no cyanide. Three different detection systems [Fourier transform Infrared (FTIR) and photodiode array spectrophotometry and a post-column reaction (PCR)], were used to determine changes that occurred to the Cu(I)-cyanide complexes during the separation with eluents containing from 0 to 100 mu M cyanide. The FTIR approach was unsuccessful due to a lack of sensistivity. The UV spectrum of the Cu(I) peak in any one eluent remained constant, irrespective of the composition of the injected sample, but there were distinct changes in this spectrum among eluents. Similarly, the R value of the Cu(I) peak determined by PCR remained the same in any one eluent but ranged from about 2.5 to about 3.4 for these eluents. The R value was found to vary within the eluted Cu(I)-cyanide peak, especially in an eluent containing no added cyanide. These results show that more than one Cu(I)-cyanide complex is present in the eluted peak and that in the absence of cyanide in the eluent, the eluted peak consists of a mixture of the di- and tricyano complexes of Cu(I).
引用
收藏
页码:165 / 174
页数:10
相关论文
共 30 条
[1]   KINETICS AND EQUILIBRIA IN COPPER(II)-CYANIDE SOLUTIONS [J].
BAXENDALE, JH ;
WESTCOTT, DT .
JOURNAL OF THE CHEMICAL SOCIETY, 1959, (JUL-A) :2347-2351
[2]  
BECK MT, 1987, PURE APPL CHEM, V59, P1704
[3]   DETERMINATION OF FREE CYANIDE IN GOLD CYANIDATION PROCESS LIQUORS BY ION-INTERACTION CHROMATOGRAPHY WITH POSTCOLUMN DERIVATIZATION [J].
FAGAN, PA ;
HADDAD, PR .
JOURNAL OF CHROMATOGRAPHY, 1991, 550 (1-2) :559-571
[4]   SEPARATION OF METAL-CYANIDE COMPLEXES BY REVERSED-PHASE ION-INTERACTION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GIROUX, L ;
BARKLEY, DJ .
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1994, 72 (02) :269-273
[5]  
GLOD BK, 1994, CHEM ANAL-WARSAW, V39, P399
[6]   SEPARATION AND DETERMINATION OF STABLE METALLO CYANIDE COMPLEXES IN METALLURGICAL PLANT SOLUTIONS AND EFFLUENTS BY REVERSED-PHASE ION-PAIR CHROMATOGRAPHY [J].
GRIGOROVA, B ;
WRIGHT, SA ;
JOSEPHSON, M .
JOURNAL OF CHROMATOGRAPHY, 1987, 410 (02) :419-426
[7]   ADVANCES IN ION CHROMATOGRAPHY - SPECIATION OF MU-G 1-1 LEVELS OF METALLO-CYANIDES USING ION-INTERACTION CHROMATOGRAPHY [J].
HADDAD, PR ;
KALAMBAHETI, C .
ANALYTICA CHIMICA ACTA, 1991, 250 (01) :21-36
[8]   DETERMINATION OF TRACE LEVELS OF GOLD(I) AS ITS CYANO COMPLEX BY ION-INTERACTION REVERSED-PHASE LIQUID-CHROMATOGRAPHY WITH ONLINE SAMPLE PRECONCENTRATION [J].
HADDAD, PR ;
ROCHESTER, NE .
ANALYTICAL CHEMISTRY, 1988, 60 (06) :536-540
[9]   CU(CH3CN)2, EIN MITTEL ZUM STUDIUM HOMOGENER REAKTIONEN DES EINWERTIGEN KUPFERS IN WASSRIGER LOSUNG [J].
HEMMERICH, P ;
SIGWART, C .
EXPERIENTIA, 1963, 19 (09) :488-&
[10]   DETERMINATION OF METAL-CYANO COMPLEXES BY REVERSED-PHASE ION-INTERACTION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND ITS APPLICATION TO THE ANALYSIS OF PRECIOUS METALS IN GOLD PROCESSING SOLUTIONS [J].
HILTON, DF ;
HADDAD, PR .
JOURNAL OF CHROMATOGRAPHY, 1986, 361 :141-150