Forecasting of life threatening arrhythmias using the compression entropy of heart rate

被引:94
作者
Baumert, M
Baier, V
Haueisen, J
Wessel, N
Meyerfeldt, U
Schirdewan, A
Voss, A
机构
[1] Univ Appl Sci Jena, Dept Med Engn, D-07745 Jena, Germany
[2] Univ Jena, Dept Neurol, Biomagnet Ctr, D-6900 Jena, Germany
[3] Univ Potsdam, Inst Phys, Potsdam, Germany
[4] Humboldt Univ, Charite, Franz Volhard Hosp, Berlin, Germany
关键词
implantable cardioverter defibrillators; heart rate variability; nonlinear dynamics;
D O I
10.1055/s-0038-1633859
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Objectives. Ventricular tachycardia (VT) provoking sudden cardiac death (SCD) are a major cause of mortality in the developed countries. The most efficient therapy for SCID prevention are implantable cardioverter defibrillators (ICD). In this study heart rate variability (HRV) measures were analyzed for short-term forecasting of VT in order to improve VT sensing and to enable a patient warning of forthcoming shocks. Methods. The lost 1000 normal beat-to-beat intervals before 50 VT episodes stored by the ICD were analyzed and compared to individually acquire control time series (CON). HRV analysis was performed with standard parameters of time and frequency domain as suggested by the HRV Task Force and furthermore with a newly developed and optimized nonlinear parameter that assesses the compression entropy of heart rate (H-c). Results. Except of meanNN (p = 0.02) we found no significant differences in standard HRV parameters. In contrast, H, revealed highly significant (p = 0.007) alterations in VT compared with CON suggesting a decreased complexity before the onset of VT. Conclusion: Compression entropy might be a suitable parameter for short-term forecasting of life-threatening tachycardia in ICD.
引用
收藏
页码:202 / 206
页数:5
相关论文
共 26 条
[1]   Language trees and zipping [J].
Benedetto, D ;
Caglioti, E ;
Loreto, V .
PHYSICAL REVIEW LETTERS, 2002, 88 (04) :4
[2]  
Camm AJ, 1996, EUR HEART J, V17, P354
[3]  
CESAR A, 2002, ACC CURRENT J REV, P77
[4]  
CHATIN GJ, 1990, INFORMATION RANDOMNE
[5]   Temporal and geographical trends in indications for implantation of cardiac defibrillators in Europe 1993-1998 [J].
Copie, X ;
Piot, O ;
Said, MA ;
Lavergne, T ;
Ollitrault, J ;
Guize, L ;
Le Heuzey, JY .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (06) :979-984
[6]   Electrogram width parameter analysis in implantable cardioverter defibrillators: Influence of body position and electrode configuration [J].
Favale, S ;
Nacci, F ;
Galati, A ;
Accogli, M ;
De Giorgi, V ;
Greco, MR ;
Nastasi, M ;
Pierfelice, O ;
Rossi, S ;
Gargaro, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (12) :1732-1738
[7]   Value of heart rate variability parameters for prediction of serious arrhythmic events in patients with malignant ventricular arrhythmias [J].
Filipecki, A ;
TruszGluza, M ;
Szydlo, K ;
Giec, L .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11) :1852-1856
[8]   Management of malignant ventricular arrhythmias and cardiac arrest [J].
Fogel, RI ;
Prystowsky, EN .
CRITICAL CARE MEDICINE, 2000, 28 (10) :N165-N169
[9]   Heart rate variability and major arrhythmic events in patients with idiopathic dilated cardiomyopathy [J].
Hoffmann, J ;
Grimm, W ;
Menz, V ;
Knop, U ;
Maisch, B .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11) :1841-1844
[10]   Abnormalities in beat-to-beat dynamics of heart rate before the spontaneous onset of life-threatening ventricular tachyarrhythmias in patients with prior myocardial infarction [J].
Huikuri, HV ;
Seppanen, T ;
Koistinen, MJ ;
Airaksinen, KEJ ;
Ikaheimo, MJ ;
Castellanos, A ;
Myerburg, RJ .
CIRCULATION, 1996, 93 (10) :1836-1844