摘要
A sensitive electrochemical detection method (ECD) for capillary electrophoresis has been developed that is applicable to a much wider range of analytes than more conventional ECD methods. Using a modified Osteryoung square-wave voltammetry method, the adsorption of what are normally considered nonelectrochemically active analytes onto a platinum electrode was found to produce a concentration-proportional response. Although the mechanisms that cause this response may be complex, it appears that it is due to changes in the electrode/solution interface that accompany adsorption of the analyte onto the electrode rather than a simple redox process. Analytes that possess pi-electron density appeared to chemisorb rather than only physically adsorb onto the electrode and gave the best response with detection Limits of <10(-8) M while maintaining good linearity. Because this detection method requires only that the analyte adsorb onto the electrode, it has the advantage of much wider applicability than previously reported electrochemical detection methods. The applicability of this detection method was investigated for a variety of analytes and background electrolyte conditions (varied pH, ionic strength, buffer additives), Comparisons of the sensitivity of this method to UV detection showed that, even for analytes that have good UV chromophores, sensitivities greater than 1 order of magnitude were obtained using adsorption-based electrochemical detection.
引用
收藏
页码:908 / 915
页数:8
相关论文
共 9 条
[1]  
[Anonymous], 1998, J CAN SOC FORENSIC S
[2]   ELECTROCATALYSIS AT PLATINUM-ELECTRODES FOR ANODIC ELECTROANALYSIS [J].
AUSTIN, DS ;
POLTA, JA ;
POLTA, TZ ;
TANG, APC ;
CABELKA, TD ;
JOHNSON, DC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 168 (1-2) :227-248
[3]   High-frequency impedance spectroscopy of platinum ultramicroelectrodes in flowing solutions [J].
Baranski, AS ;
Krogulec, T ;
Nelson, LJ ;
Norouzi, P .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2895-2901
[4]   Voltammetric determination of surface active compounds at Au and Pt ultramicroelectrodes in flowing solutions [J].
Baranski, AS ;
Norouzi, P .
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1997, 75 (11) :1736-1749
[5]   Square-wave voltammetry detection for capillary electrophoresis [J].
Gerhardt, GC ;
Cassidy, RM ;
Baranski, AS .
ANALYTICAL CHEMISTRY, 1998, 70 (10) :2167-2173
[6]  
HUDSON JC, 1995, J CAN SOC FORENSIC S, V28, P137
[7]  
LACOURSE RW, 1998, ADV CHROMATOGR, P189
[8]  
Lipkowski J., 1992, ADSORPTION MOL METAL
[9]   THE BEHAVIOR OF MICROELECTRODES [J].
PONS, S ;
FLEISCHMANN, M .
ANALYTICAL CHEMISTRY, 1987, 59 (24) :A1391-A1399