Biosensors for marine pollution research, monitoring and control

被引:44
作者
Kröger, S
Piletsky, S
Turner, APF
机构
[1] CEFAS, Lowestoft NR33 0HT, Suffolk, England
[2] Cranfield Univ, Bedford MK45 4DT, England
关键词
marine biosensors; decentralised measurements; novel instrumentation; analytical techniques; chemical pollution; pollution monitoring;
D O I
10.1016/S0025-326X(01)00309-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Measurement of ecological, climatic and anthropogenic changes underpins the formulation of effective management strategies for sustainable use and protection of the marine environment. Sensors are traditionally used in marine studies to determine physical parameters, but there is increasing demand for real-time information about chemical and biological parameters. These parameters are currently measured in samples collected at sea and subsequently analysed in the laboratory. Biosensors fuse the exquisite sensitivity and specificity of living systems with the processing power of microelectronics to deliver simple, inexpensive measurement systems for use in the field or deployment in situ. While their potential for use in the marine environment is enormous, much published work to date has focussed on applications in freshwater and wastewater. Marine applications pose a substantial challenge in the robustness required for remote application, but recent developments in portable medical devices and receptor design suggest that these demands can now be realistically tackled. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:24 / 34
页数:11
相关论文
共 100 条
[1]   Optical biosensing of nitrate ions using a sol-gel immobilized nitrate reductase [J].
Aylott, JW ;
Richardson, DJ ;
Russell, DA .
ANALYST, 1997, 122 (01) :77-80
[2]   Amplified electronic transduction of oligonucleotide interactions: novel routes for Tay-Sachs biosensors [J].
Bardea, A ;
Dagan, A ;
Willner, I .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :33-43
[3]  
BILITEWSKI U, 2000, BIOSENSORS ENV MONIT, P409
[4]   Development of a green fluorescent protein reporter for a yeast genotoxicity biosensor [J].
Billinton, N ;
Barker, MG ;
Michel, CE ;
Knight, AW ;
Heyer, WD ;
Goddard, NJ ;
Fielden, PR ;
Walmsley, RM .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) :831-838
[5]  
CARDOSI MF, 1990, DIABETES ANN, V5, P254
[6]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[7]   Inter-laboratory comparison of liquid chromatographic techniques and enzyme-linked immunosorbent assay for the determination of surfactants in wastewaters [J].
Castillo, M ;
Riu, J ;
Ventura, F ;
Boleda, R ;
Scheding, R ;
Schröder, HF ;
Nistor, C ;
Émneus, J ;
Eichhorn, P ;
Knepper, TP ;
Jonkers, CCA ;
de Voogt, P ;
González-Mazo, E ;
León, VM ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 2000, 889 (1-2) :195-209
[8]   Identification of cytotoxic compounds in European wastewaters during a field experiment [J].
Castillo, M ;
Alonso, MC ;
Riu, J ;
Reinke, M ;
Klöter, G ;
Dizer, H ;
Fischer, B ;
Hansen, PD ;
Barceló, D .
ANALYTICA CHIMICA ACTA, 2001, 426 (02) :265-277
[9]   DNA optical sensor: a rapid method for the detection of DNA hybridization [J].
Chen, X ;
Zhang, XE ;
Chai, YQ ;
Hu, WP ;
Zhang, ZP ;
Zhang, XM ;
Cass, AEG .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4) :451-458
[10]   AMPEROMETRIC DETECTION OF NITRATE VIA A NITRATE REDUCTASE IMMOBILIZED AND ELECTRICALLY WIRED AT THE ELECTRODE SURFACE [J].
COSNIER, S ;
INNOCENT, C ;
JOUANNEAU, Y .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3198-3201