Bio-sensing textile based patch with integrated optical detection system for sweat monitoring

被引:182
作者
Morris, Deirdre [1 ]
Coyle, Shirley [1 ]
Wu, Yanzhe [1 ,2 ]
Lau, King Tong [1 ]
Wallace, Gordon [2 ]
Diamond, Dermot [1 ]
机构
[1] Dublin City Univ, Sch Chem Sci, Natl Ctr Sensor Res, Adapt Sensors Grp, Dublin 9, Ireland
[2] Univ Wollongong, Intelligent Polymer Res Inst, Wollongong, NSW 2522, Australia
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2009年 / 139卷 / 01期
基金
爱尔兰科学基金会;
关键词
Wearable systems; Fluid handling; Biochemical sensors; Wireless monitoring; pH sensor; EXERCISE; CARE; PH;
D O I
10.1016/j.snb.2009.02.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sensors, which can be integrated into clothing and used to measure biochemical changes in body fluids, Such as sweat, constitute a major advancement in the area of wearable sensors. Initial applications for Such technology exist in personal health and sports performance monitoring. However, sample collection is a complicated matter as analysis must be done in real-time in order to obtain a useful examination of its composition. This work Outlines the development of a textile-based fluid handling platform which uses a passive pump to gather sweat and move it through a pre-defined channel for analysis. The system is tested both in vitro and in vivo. In addition, a pH sensor, which depends on the use of a pH sensitive dye and paired emitter-detector LEDs to measure colour changes, has been developed. In vitro and on-body trials have shown that the sensor has the potential to record real-time variations in sweat during exercise. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:231 / 236
页数:6
相关论文
共 28 条
[1]   Primary care:: Hyponatremia. [J].
Adrogué, HJ ;
Madias, NE .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (21) :1581-1589
[2]  
*AIS DEP SPORTS NU, 2004, MUCH DO ATHL SWEAT D, P1
[3]   A SIMPLE AND DISPOSABLE SWEAT COLLECTOR [J].
BRISSON, GR ;
BOISVERT, P ;
PERONNET, F ;
PERRAULT, H ;
BOISVERT, D ;
LAFOND, JS .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1991, 63 (3-4) :269-272
[4]   EFFECTS OF CARBON DIOXIDE INHALATION ON SWEATING [J].
BULLARD, RW .
JOURNAL OF APPLIED PHYSIOLOGY, 1964, 19 (01) :137-&
[5]  
Burry J. S., 2001, International Journal of Cosmetic Science, V23, P99, DOI 10.1046/j.1467-2494.2001.00085.x
[6]  
Casa DJ, 2000, J ATHL TRAINING, V35, P212
[7]  
COYLE S, 2007, 4 INT WORKSH WEAR IM
[8]   Wireless sensor networks and chemo-/biosensing [J].
Diamond, Dermot ;
Coyle, Shirley ;
Scarmagnani, Silvia ;
Hayes, Jer .
CHEMICAL REVIEWS, 2008, 108 (02) :652-679
[9]   Na+/H+ exchangers in the human eccrine sweat duct [J].
Granger, D ;
Marsolais, M ;
Burry, J ;
Laprade, R .
AMERICAN JOURNAL OF PHYSIOLOGY-CELL PHYSIOLOGY, 2003, 285 (05) :C1047-C1058
[10]   The reproducibility of closed-pouch sweat collection and thermoregulatory responses to exercise-heat stress [J].
Hayden, G ;
Milne, HC ;
Patterson, MJ ;
Nimmo, MA .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2004, 91 (5-6) :748-751