A comparison of kangaroo mother care and conventional incubator care for thermal regulation of infants <2000 g in Nigeria using continuous ambulatory temperature monitoring

被引:48
作者
Ibe, OE
Austin, T
Sullivan, K
Fabanwo, O
Disu, E
Costello, AMD
机构
[1] UCL, Inst Child Hlth, Int Perinatal Care Unit, London WC1N 1EH, England
[2] POLICY Project, Abuja, Nigeria
[3] Lagos State Univ Teaching Hosp, Lagos, Nigeria
[4] UCL Hosp, London, England
来源
ANNALS OF TROPICAL PAEDIATRICS | 2004年 / 24卷 / 03期
关键词
D O I
10.1179/027249304225019082
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Although skin-to-skin contact (or kangaroo mother care, KMC) for preterm infants is a practical alternative to incubator care, no studies have compared these methods using continuous ambulatory temperature monitoring. To compare thermal regulation in low birthweight infants (<2000 g) managed by KMC alternating with conventional care (CC) and to determine the acceptability to mothers of KMC, an experimental study with a crossover design with observational and qualitative data collected on temperature patterns and mothers attitudes to skin-to-skin care was conducted in the neonatal wards of three hospitals in Lagos, Nigeria. Thirteen eligible infants were nursed by their mothers or surrogates in 38 4-hour sessions of KMC and the results compared with 38 sessions of incubator care. The risk of hypothermia was reduced by >90% when nursed by KMC rather than conventional care, relative risk (RR) 0.09 (0.03-0.25). More cases of hyperthermia (>37.5degreesC) occurred with KMC, and core-periphery temperature differences were widened, but the risk of hyperthermia >37.9degreesC (RR 1.3, 0.9-1.7) was not significant. Micro-ambient temperatures were higher during KMC, although the average room temperatures during both procedures did not differ significantly. Mothers felt that KMC was safe, and preferred the method to CC because it did not separate them from their infants, although some had problems adjusting to this method of care. Where equipment for thermal regulation is lacking or unreliable, KMC is a preferable method for managing stable low birthweight infants.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 28 条
[1]   OXYGENATION, HEART-RATE AND TEMPERATURE IN VERY LOW-BIRTH-WEIGHT INFANTS DURING SKIN-TO-SKIN CONTACT WITH THEIR MOTHERS [J].
ACOLET, D ;
SLEATH, K ;
WHITELAW, A .
ACTA PAEDIATRICA SCANDINAVICA, 1989, 78 (02) :189-193
[2]  
AJAYI OA, 1998, ANN GEN SCI C PAED A
[3]  
Anderson G C, 1991, J Perinatol, V11, P216
[4]   SIMPLIFIED SCORE FOR ASSESSMENT OF FETAL MATURATION OF NEWLY BORN INFANTS [J].
BALLARD, JL ;
NOVAK, KK ;
DRIVER, M .
JOURNAL OF PEDIATRICS, 1979, 95 (05) :769-774
[5]  
BAUER K, 1997, J PEDIATR, V130, P241
[6]   INFANT INCUBATORS AND RADIANT WARMERS [J].
BELL, EF .
EARLY HUMAN DEVELOPMENT, 1983, 8 (3-4) :351-375
[7]   THE KANGAROO-METHOD FOR TREATING LOW-BIRTH-WEIGHT BABIES IN A DEVELOPING-COUNTRY [J].
BERGMAN, NJ ;
JURISOO, LA .
TROPICAL DOCTOR, 1994, 24 (02) :57-60
[8]  
Bosque E M, 1995, J Obstet Gynecol Neonatal Nurs, V24, P219, DOI 10.1111/j.1552-6909.1995.tb02466.x
[9]  
BRUCK K, 1961, BIOL NEONATE, V3, P65
[10]  
BUETOW KC, 1964, PEDIATRICS, V34, P163