Usefulness of gadolinium-enhanced MR imaging in the evaluation of the vascularity of scaphoid nonunions

被引:91
作者
Cerezal, L [1 ]
Abascal, F
Canga, A
García-Valtuille, R
Bustamante, M
del Piñal, F
机构
[1] Hosp Mompia, Dept Radiol, Mompia 39100, Cantabria, Spain
[2] Hosp Santa Cruz, Dept Radiol, Liencres 39120, Cantabria, Spain
[3] Univ Hosp Marques Valdecilla, Dept Radiol, Santander 39008, Spain
[4] Hosp Mutua Montanesa, Unit Hand Surg, Santander 39012, Spain
关键词
D O I
10.2214/ajr.174.1.1740141
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of this article is to identify the role of gadolinium-enhanced MR imaging in the preoperative evaluation of the vascular status of the proximal fragment in scaphoid nonunions. SUBJECTS AND METHODS. Thirty consecutive patients (27 men and three women; age range, 19-52 years; mean age, 28 years) with nonunion of the scaphoid were prospectively examined with unenhanced and gadolinium-enhanced MR imaging. MR images and surgical findings were classified in four groups according to the vascular status of the proximal fragment (normal bone, moderate ischemic bone, severe ischemic bone, and avascular necrosis). Sensitivity, specificity, and accuracy of unenhanced and gadolinium-enhanced MR studies were calculated. Surgical findings were used as the gold standard. The postoperative rate of union at 12 months was evaluated for each group. RESULT. Unenhanced MR imaging showed a global sensitivity of 36%, specificity of 78%, and accuracy of 68% in the preoperative evaluation of the vascular status of the proximal fragment. Correlation with the surgical findings was not statistically significant (p < 0.149), Global sensitivity, specificity, and accuracy of gadolinium-enhanced MR imaging were 66%, 88%, and 83%, respectively. Correlation with the surgical findings was good (p < 0.0001). Gadolinium-enhanced sequences allowed accurate diagnosis and enabled the creation of prognostic groups having better correlation with surgical findings and postoperative results. CONCLUSION. Gadolinium-enhanced MR imaging is the most reliable imaging method for investigating the vascularity of the proximal pole in scaphoid nonunions.
引用
收藏
页码:141 / 149
页数:9
相关论文
共 35 条
[1]  
AMADIO PC, 1992, ORTHOP CLIN N AM, V1, P7
[2]   RADIOSCAPHOLUNATE LIGAMENT - A GROSS ANATOMIC AND HISTOLOGIC-STUDY OF FETAL AND ADULT WRISTS [J].
BERGER, RA ;
KAUER, JMG ;
LANDSMEER, JMF .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1991, 16A (02) :350-354
[3]   FRACTURE OF THE CARPAL SCAPHOID - FREQUENCY AND DISTRIBUTION IN A WELL-DEFINED POPULATION [J].
BRONDUM, V ;
LARSEN, CF ;
SKOV, O .
EUROPEAN JOURNAL OF RADIOLOGY, 1992, 15 (02) :118-122
[4]   SCAPHOID NONUNION - ROLE OF ANTERIOR INTERPOSITIONAL BONE-GRAFTS [J].
COONEY, WP ;
LINSCHEID, RL ;
DOBYNS, JH ;
WOOD, MB .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (05) :635-650
[5]   NONUNION OF THE SCAPHOID - ANALYSIS OF THE RESULTS FROM BONE-GRAFTING [J].
COONEY, WP ;
DOBYNS, JH ;
LINSCHEID, RL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1980, 5 (04) :343-354
[6]   SCAPHOID FRACTURES AND KIENBOCKS DISEASE OF THE LUNATE - MR IMAGING WITH HISTOPATHOLOGIC CORRELATION [J].
DESSER, TS ;
MCCARTHY, S ;
TRUMBLE, T .
MAGNETIC RESONANCE IMAGING, 1990, 8 (04) :357-361
[7]   LONG-TERM RESULTS OF FRACTURE OF THE SCAPHOID - A FOLLOW-UP-STUDY OF MORE THAN 30 YEARS [J].
DUPPE, H ;
JOHNELL, O ;
LUNDBORG, G ;
KARLSSON, M ;
REDLUNDJOHNELL, I .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (02) :249-252
[8]   ANTERIOR BONE-GRAFTING AND CONVENTIONAL LAG SCREW FIXATION TO TREAT SCAPHOID NONUNIONS [J].
FERNANDEZ, DL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1990, 15A (01) :140-147
[9]   NONUNION OF THE SCAPHOID - REVASCULARIZATION OF THE PROXIMAL POLE WITH IMPLANTATION OF A VASCULAR BUNDLE AND BONE-GRAFTING [J].
FERNANDEZ, DL ;
EGGLI, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (06) :883-893
[10]  
FERNANDEZ DL, 1992, WRISTS DISORDERS, P153