Comparison of microcomputed tomographic and microradiographic measurements of cortical bone porosity

被引:115
作者
Cooper, DML
Matyas, JR
Katzenberg, MA
Hallgrimsson, B
机构
[1] Univ Calgary, Dept Cell Biol & Anat, Calgary, AB T2N 4N1, Canada
[2] Univ Calgary, Dept Archaeol, Calgary, AB T2N 4N1, Canada
[3] Univ Calgary, Dept Med Sci, Calgary, AB T2N 4N1, Canada
[4] Univ Calgary, Joint Injury & Arthrit Res Grp, Calgary, AB T2N 4N1, Canada
[5] Univ Calgary, Dept Pathol & Lab Med, Calgary, AB T2N 4N1, Canada
关键词
cortical porosity; bone histology and histomorphometry microcomputed tomography; microradiography; bone microstructure;
D O I
10.1007/s00223-003-0071-z
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Cortical bone is perforated by a network of canals that have a significant impact upon its material properties. Microcomputed tomography offers the possibility of noninvasively visualizing and quantifying cortical pores in both two and three dimensions. Establishing how two-dimensional (2D) microcomputed tomographic (muCT) analysis compares with conventional methods for analyzing cortical porosity is an important prerequisite for the wider adoption of this technique and the development of three-dimensional (3D) analysis. Therefore, we compared porosity-related parameters from 2D microcomputed tomographic images with those from matching microradiographic sections. Samples from five human femora were scanned at a 10-mum resolution and then sequentially sectioned and microradiographed. An average of eight image pairs were produced from each femur (total, n = 41). The repeatability and comparability of the two techniques was assessed for three parameters; cortical porosity and mean pore area (mum(2)), and pore density (pores/mm(2)). For repeatability. no significant difference (P > 0.05) was found between the two methods for cortical porosity (%), mean pore area, however, pore density differed significantly (P < 0.001). For comparability, the bias (+/- error) between the methods was found to be 0.51% (+/- 0.31%) for cortical porosity and -155 mu m(2) (+/- 293 mu m(2)) for mean pore area. The bias for pore density was dependent upon measurement size with microcomputed tomographic images having 14% (+/- 9.3%) fewer pores per millimeter squared. The qualitative and quantitative similarities between the two techniques demonstrated the utility of 2D microcomputed tomographic for cortical porosity analysis. However, the relatively poor results for pore density revealed that a higher resolution (< 10 mum) is needed to consistently visualize all cortical pores in human bone.
引用
收藏
页码:437 / 447
页数:11
相关论文
共 38 条
[1]
MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]
The visualization and evaluation of bone architecture in the rat using three-dimensional X-Ray microcomputed tomography [J].
Barbier, A ;
Martel, C ;
de Vernejoul, MC ;
Tirode, F ;
Nys, M ;
Mocaer, G ;
Morieux, C ;
Murakami, H ;
Lacheretz, F .
JOURNAL OF BONE AND MINERAL METABOLISM, 1999, 17 (01) :37-44
[3]
High-resolution three-dimensional micro-computed tomography detects bone loss and changes in trabecular architecture early - Comparison with DEXA and bone histomorphometry in a rat model of disuse osteoporosis [J].
Barou, O ;
Valentin, D ;
Vico, L ;
Tirode, C ;
Barbier, A ;
Alexandre, C ;
Lafage-Proust, MH .
INVESTIGATIVE RADIOLOGY, 2002, 37 (01) :40-46
[4]
BARTH RW, 1992, CLIN ORTHOP RELAT R, P178
[5]
Super-osteons (remodeling clusters) in the cortex of the femoral shaft: Influence of age and gender [J].
Bell, KL ;
Loveridge, N ;
Reeve, J ;
Thomas, CDL ;
Feik, SA ;
Clement, JG .
ANATOMICAL RECORD, 2001, 264 (04) :378-386
[6]
3D COMPUTED X-RAY TOMOGRAPHY OF HUMAN CANCELLOUS BONE AT 8 MU-M SPATIAL AND 10(-4) ENERGY RESOLUTION [J].
BONSE, U ;
BUSCH, F ;
GUNNEWIG, O ;
BECKMANN, F ;
PAHL, R ;
DELLING, G ;
HAHN, M ;
GRAEFF, W .
BONE AND MINERAL, 1994, 25 (01) :25-38
[7]
THE 3-DIMENSIONAL ANATOMY OF HAVERSIAN SYSTEMS [J].
COHEN, J ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1958, 40 (02) :419-434
[8]
COOPER DML, 2001, AM J PHYS ANTHROPOL, V117, P56
[9]
COOPER DML, 2003, IN PRESS ANAT REC