The impact of ionic strength and background electrolyte on pH measurements in metal ion adsorption experiments

被引:51
作者
Wiesner, Andrew D. [1 ]
Katz, Lynn E. [1 ]
Chen, Chia-Chen [1 ]
机构
[1] Univ Texas, Coll Engn, Dept Civil Architectural & Environm Engn, Austin, TX 78712 USA
关键词
adsorption; surface complexation; ionic strength; pH electrode calibration; cobalt; gibbsite; RAY-ABSORPTION-SPECTROSCOPY; WATER INTERFACES; SORPTION; THERMODYNAMICS; CO(II);
D O I
10.1016/j.jcis.2006.05.011
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Our understanding of metal ion adsorption to clay minerals has progressed significantly over the past several decades, and theories have been promulgated to describe and predict the impacts of pH, ionic strength, and background solution composition on the extent of adsorption. Studies evaluating the effects of ionic strength on adsorption typically employ a broad range of background electrolyte concentrations. Measurement of pH in these systems can be inaccurate when pH values are measured with liquid junction pH probes calibrated with standard buffers due to changes in the liquid junction potential between standard, low ionic strength (0.05 M) buffers and high ionic strength solutions (> 0.1 M). The objective of this research is to determine the extent of the error in pH values measured at high ionic strength, and to develop an approach for accurately measuring pH over a range of ionic strengths using a combined pH electrode. To achieve this objective, the adsorption of cobalt (10(-5) M) onto gibbsite (10 g/L) from various electrolyte solutions (0.01-1 M) was studied. The pH measurements were determined from calibrations with standard buffers and ionic strength corrected buffer calibrations. The results show a significant effect of the aqueous solution background electrolyte anion and ionic strength on pH measurement. The 0.5 and 1 M ionic strength metal ion adsorption edges shifted to lower pH with increasing ionic strength when pH was calibrated with standard buffers whereas no shift in the adsorption edges was observed when calibrated with ionic strength corrected buffers. Therefore, to obtain an accurate pH measurement, pH calibration should contain the same electrolyte and ionic strength as the samples. (c) 2006 Published by Elsevier Inc.
引用
收藏
页码:329 / 332
页数:4
相关论文
共 13 条
[1]   DETERMINATION OF PH IN CONCENTRATED SALT SOLUTIONS [J].
BAUMANN, EW .
ANALYTICA CHIMICA ACTA, 1973, 64 (02) :284-288
[2]   Comparison of several calibration procedures for glass electrodes in proton concentration [J].
Brandariz, I ;
Barriada, JL ;
Vilariñio, T ;
de Vicente, MES .
MONATSHEFTE FUR CHEMIE, 2004, 135 (12) :1475-1488
[3]   Effect of ionic strength on the formal potential of the glass electrode in various saline media [J].
Brandariz, I ;
Vilarino, T ;
Alonso, P ;
Herrero, R ;
Fiol, S ;
de Vicente, MES .
TALANTA, 1998, 46 (06) :1469-1477
[4]   X-ray absorption spectroscopy investigation of aqueous Co(II) and Sr(II) sorption at clay-water interfaces [J].
Chen, CC ;
Hayes, KF .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1999, 63 (19-20) :3205-3215
[5]   EVIDENCE FOR MULTINUCLEAR METAL-ION COMPLEXES AT SOLID WATER INTERFACES FROM X-RAY ABSORPTION-SPECTROSCOPY [J].
CHISHOLMBRAUSE, CJ ;
ODAY, PA ;
BROWN, GE ;
PARKS, GA .
NATURE, 1990, 348 (6301) :528-531
[6]   Adsorption of nitrilotriacetate (NTA), Co and CoNTA by gibbsite [J].
Girvin, DC ;
Gassman, PL ;
Bolton, H .
CLAYS AND CLAY MINERALS, 1996, 44 (06) :757-768
[7]   MODELING IONIC-STRENGTH EFFECTS ON ANION ADSORPTION AT HYDROUS OXIDE SOLUTION INTERFACES [J].
HAYES, KF ;
PAPELIS, C ;
LECKIE, JO .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1988, 125 (02) :717-726
[8]  
Katz LE, 2001, SSSA SPEC PUBL, V56, P213
[9]   A critique of diffuse double layer models applied to colloid and surface chemistry [J].
McBride, MB .
CLAYS AND CLAY MINERALS, 1997, 45 (04) :598-608
[10]   THERMODYNAMICS OF ELECTROLYTES .2. ACTIVITY AND OSMOTIC COEFFICIENTS FOR STRONG ELECTROLYTES WITH ONE OR BOTH IONS UNIVALENT [J].
PITZER, KS ;
MAYORGA, G .
JOURNAL OF PHYSICAL CHEMISTRY, 1973, 77 (19) :2300-2308