Determination of trace lead, cadmium and mercury by on-line column enrichment followed by RP-HPLC as metal-tetra-(4-bromophenyl)-porphyrin chelates

被引:89
作者
Hu, QF
Yang, GY [1 ]
Yin, JY
Yao, Y
机构
[1] Yunnan Univ, Dept Chem, Kunming 650091, Peoples R China
[2] Yuxi Normal Coll, Dept Chem, Yuxi 653100, Peoples R China
关键词
RP-HPLC; tetra-(4-bromophenyl)-porphyrin; on-line column enrichment; lead; cadmium; mercury;
D O I
10.1016/S0039-9140(02)00096-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports the utilization of tetra-(4-bromophenyl)-porphyrin (T4BPP) as a chelating reagent using Waters Xterra(TM) RP18 column for the on-line column enrichment and the separation of trace lead, cadmium and mercury ions by reversed-phase high-performance liquid chromatography (RP-HPLC) with photodiode array detector. When the Hg-T4BPP, Pb-T4BPP and Cd-T4BPP chelates were injected into the injector and sent to the enrichment column with 0.05 mol l(-1) of pH 10.0 pyrrolidine-phosphoric acid buffer solution (containing 10% of tetrahydrofuran (THF)) as mobile phase. The chelates were retained on the top of the enrichment column. After the enrichment is finished, by switching the valve of six-ports switching valve, the retained metal-T4BPP chelates will be eluted by mobile phase in reverse direction and will travel towards analytical column. With THF (containing 0.05 mol l(-1), pH 10.0 pyrrolidine-phosphoric acid buffer salt) and 0.05 mol l(-1), pH 10.0 pyrrolidine-phosphoric acid buffer solution (containinging 10% THF) gradient elution as mobile phase, the chelates separation on the analytical column was satisfactory. The linearity ranges are 0.01-120 mug l(-1) for each metal ion. The detection limits (S/N = 3) of lead, cadmium and mercury are 1.0, 0.5 and 1.0 ng l(-1), respectively. This method can be applied to the determination (mug l(-1)) level of lead, cadmium and mercury in drinking water with satisfactory results. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:751 / 756
页数:6
相关论文
共 13 条
[1]  
Chen XH, 2000, CHINESE J ANAL CHEM, V28, P1260
[2]  
CHENG JK, 1995, CHEM J CHINESE U, V16, P696
[3]  
CHENG JK, 1990, CHINESE J ANAL CHEM, V18, P876
[4]  
*CHIN ENV PROT AG, 1989, ANAL METHOD WATER WA
[5]   SEPARATION OF METAL TETRAKIS(P-TOLYL)PORPHINE COMPLEXES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KOBAYASHI, M ;
SAITOH, K ;
SUZUKI, N .
CHROMATOGRAPHIA, 1985, 20 (02) :72-74
[6]  
*NAT STAND PEOPL R, 574985 GBT
[7]   METAL DETERMINATION AND METAL SPECIATION BY LIQUID-CHROMATOGRAPHY - A REVIEW [J].
ROBARDS, K ;
STARR, P .
ANALYST, 1991, 116 (12) :1247-1273
[8]  
SHI ZH, 2000, CHINESE J CHROMATOGR, V18, P27
[9]  
SHI ZH, 1996, CHIN J ANAL TESTING, V2, P28
[10]  
XU F, 1995, ACTA ZHEJIANG NORMAL, V18, P34