A multi-analyte method for the quantification of contemporary pesticides in human serum and plasma using high-resolution mass spectrometry

被引:132
作者
Barr, DB
Barr, JR
Maggio, VL
Whitehead, RD
Sadowski, MA
Whyatt, RM
Needham, LL
机构
[1] Ctr Dis Control & Prevent, Natl Ctr Environm Hlth, Div Sci Lab, Atlanta, GA 30341 USA
[2] Columbia Univ, Mailman Sch Publ Hlth, Columbia Ctr Childrens Environm Hlth, New York, NY USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 778卷 / 1-2期
关键词
pesticides;
D O I
10.1016/S0378-4347(01)00444-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have developed a sensitive and accurate analytical method for quantifying 29 contemporary pesticides in human serum or plasma. These pesticides include organophosphates, carbamates, chloroacetanilides, and synthetic pyrethroids among others and include pesticides used in agricultural and residential settings. Our method employs a simple solid-phase extraction followed by a highly selective analysis using isotope dilution gas chromatography-high-resolution mass spectrometry. Our method is very accurate, has limits of detection in the low pg/g range and coefficients of variation of typically less than 20% at the low pg/g end of the method linear range. We have used this method to measure plasma pesticide concentrations in females living in an urban area. We found detectable concentrations of carbaryl/naphthalene, propoxur, bendiocarb, chlorpyrifos, diazinon, dicloran, captan and folpet or their metabolites in more than 20% of the plasma samples tested. Published by Elsevier Science B.V.
引用
收藏
页码:99 / 111
页数:13
相关论文
共 33 条
  • [1] [Anonymous], 1987, Quality Assurance of Chemical Measurements
  • [2] Strategies for biological monitoring of exposure for contemporary-use pesticides
    Barr, DB
    Barr, JR
    Driskell, WJ
    Hill, RH
    Ashley, DL
    Needham, LL
    Head, SL
    Sampson, EJ
    [J]. TOXICOLOGY AND INDUSTRIAL HEALTH, 1999, 15 (1-2) : 168 - 179
  • [3] BARR JR, 1998, TOXICOL ENVIRON CHEM, V66, P3
  • [4] Cho Y, 1997, CHEM PHARM BULL, V45, P737, DOI 10.1248/cpb.45.737
  • [5] COMPARISON OF CALCULATION PROCEDURES FOR ISOTOPE-DILUTION DETERMINATIONS USING GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    COLBY, BN
    MCCAMAN, MW
    [J]. BIOMEDICAL MASS SPECTROMETRY, 1979, 6 (06): : 225 - 230
  • [6] QUANTITATION OF PARAQUAT IN SERUM BY HPLC
    CROES, K
    MARTENS, F
    DESMET, K
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (05) : 310 - 312
  • [7] FLANAGAN RJ, 1989, CLIN CHEM, V35, P1342
  • [8] DETECTION AND ASSAY OF ORGANOPHOSPHATE PESTICIDES IN HUMAN-BLOOD BY GAS-CHROMATOGRAPHY
    FOURNIER, E
    SONNIER, M
    DALLY, S
    [J]. CLINICAL TOXICOLOGY, 1978, 12 (04): : 457 - 462
  • [9] Rapid multimethod for verification and determination of toxic pesticides in whole blood by means of capillary GC-MS
    Frenzel, T
    Sochor, H
    Speer, K
    Uihlein, M
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2000, 24 (05) : 365 - 371
  • [10] Application of high-performance thin-layer chromatography for the detection of organophosphorus insecticides in human serum after acute poisoning
    Futagami, K
    Narazaki, C
    Kataoka, Y
    Shuto, H
    Oishi, R
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1997, 704 (1-2): : 369 - 373