HLA sensitization in ventricular assist device recipients: Does type of device make a difference?

被引:35
作者
Kumpati, GS
Cook, DJ
Blackstone, EH
Rajeswaran, J
Abdo, AS
Young, JB
Starling, RC
Smedira, NG
McCarthy, PM
机构
[1] Cleveland Clin Fdn, Dept Thorac & Cardiovasc Surg, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Allogen Lab, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Dept Biostat & Epidemiol, Cleveland, OH 44195 USA
[4] Cleveland Clin Fdn, Dept Cardiovasc Med, Cleveland, OH 44195 USA
关键词
D O I
10.1016/j.jtevs.2004.01.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We sought to (1) characterize the temporal pattern of T-cell panel reactive antibody during ventricular assist device support, (2) identify predictors of higher T-cell panel reactive antibody during ventricular assist device support, and (3) determine whether device type remained a predictor after accounting for nonrandom device selection. Methods: Between December 1991 and August 2000, 239 patients received implantable ventricular assist devices, of whom 231 had T-cell panel reactive antibody measured. Panel reactive antibody was measured before implantation of the assist device, approximately 2 weeks after device implantation, irregularly thereafter depending on clinical events and length of support, and at transplantation. Longitudinal mixed modeling was used to characterize the temporal pattern of sensitization and its predictors during ventricular assist device support. To account for nonrandom factors in device selection when comparing HeartMate (Thermo Cardiosystems, Inc, Woburn, Mass) and Novacor (Baxter Healthcare Corp, Novacor Div, Oakland, Calif) devices, we propensity-matched patients according to baseline characteristics. Results: T-cell panel reactive antibody increased rapidly after implantation of the ventricular assist device and then immediately began to decrease. Predictors of higher T-cell panel reactive antibody during support with the assist device were a shorter interval from device implantation to T-cell panel reactive antibody measurement (P < .0001), female sex (P = .0004), younger age (P =.01), higher T-cell panel reactive antibody before device implantation (P = .03), more perioperative red blood cell transfusions (P = .006), and an earlier date of device implantation (P =. 001). In matched patients, device type was not a predictor of higher T-cell panel reactive antibody during ventricular assist device support (P = .8). Conclusions: HLA sensitization during ventricular assist device support is not constant but increases rapidly at implantation and then decreases. This temporal pattern of sensitization is influenced by patient factors and not by the type of device.
引用
收藏
页码:1800 / 1807
页数:8
相关论文
共 25 条
[1]  
ADDONIZIO VP, 1979, BLOOD, V53, P1033
[2]   Activation-induced T-cell death and immune dysfunction after implantation of left-ventricular assist device [J].
Ankersmit, HJ ;
Tugulea, S ;
Spanier, T ;
Weinberg, AD ;
Artrip, JH ;
Burke, EM ;
Flannery, M ;
Mancini, D ;
Rose, EA ;
Edwards, NM ;
Oz, MC ;
Itescu, S .
LANCET, 1999, 354 (9178) :550-555
[3]   Transitory immunologic response after implantation of the DeBakey VAD continuous-axial-flow pump [J].
Ankersmit, HJ ;
Wieselthaler, G ;
Moser, B ;
Gerlitz, S ;
Roth, G ;
Boltz-Nitulescu, G ;
Wolner, E .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (03) :557-561
[4]  
[Anonymous], 2002, ANAL LONGITUDINAL DA
[5]   The clinical significance of flow cytometry crossmatching in heart transplantation - Conference discussion [J].
Hasse, J ;
Bishay, ES .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (04) :369-369
[6]   Comparing apples and oranges [J].
Blackstone, EH .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (01) :8-15
[7]   NEOINTIMAL DEVELOPMENT ON TEXTURED BIOMATERIAL SURFACES DURING CLINICAL USE OF AN IMPLANTABLE LEFT-VENTRICULAR ASSIST DEVICE [J].
GRAHAM, TR ;
DASSE, K ;
COUMBE, A ;
SALIH, V ;
MARRINAN, MT ;
FRAZIER, OH ;
LEWIS, CT .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1990, 4 (04) :182-190
[8]  
HIMMELREICH G, 1995, ASAIO J, V41, pM790, DOI 10.1097/00002480-199507000-00122
[9]   Immunobiology of left ventricular assist devices [J].
Itescu, S ;
Ankersmit, JH ;
Kocher, AA ;
Schuster, MD .
PROGRESS IN CARDIOVASCULAR DISEASES, 2000, 43 (01) :67-80
[10]  
Johnson MR, 1997, J HEART LUNG TRANSPL, V16, P801