Monitoring of ancient buildings by the thermal method

被引:177
作者
Grinzato, E [1 ]
Bison, PG [1 ]
Marinetti, S [1 ]
机构
[1] CNR ITEF, I-35127 Padua, Italy
关键词
IR thermography; hygrometric conditions; CFD code;
D O I
10.1016/S1296-2074(02)01159-7
中图分类号
K85 [文物考古];
学科分类号
0601 ;
摘要
IT thermography is applied for several important purposes in the monitoring of historical buildings; among them, is here presented the monitoring of the wall's hidden structure, the finishing status and the moisture content. Furthermore, an improved technique for the thermal properties measuring porous material is also described. Dedicated thermal models are used to optimise the transient or quasi-stationary testing procedure. Both hardware and software tools are set up to implement updated thermographic equipment in order to fit specific requirements for in site dynamic tests.
引用
收藏
页码:21 / 29
页数:9
相关论文
共 14 条
[1]  
[Anonymous], THEORY PRACTICE INFR
[2]  
BAGGIO P, 1994, TERMOTECNICA JAN, P73
[3]  
BOMBER GM, 1978, ASTM, P211
[4]  
GRINZATO E, 2000, P 15TH WORLD C NDT
[5]  
GRINZATO E, 1994, RES NONDESTRUCTIVE E, V5
[6]  
GRINZATO E, 2000, SPIE, V4020, P314
[7]  
GRINZATO E, 1999, SPIE, V3700, P471
[8]  
JENKINS DR, 2000, MOISTURE MIGRATION, P207
[9]  
LJUNGBERG SA, 1994, NONDES TEST, V7, P211
[10]  
MOORES PO, 2001, ASNT NONDESTRUCTIVE