Electrospray sample deposition for matrix-assisted laser desorption/ionization (MALDI) and atmospheric pressure MALDI mass spectrometry with attomole detection limits

被引:52
作者
Wei, H
Nolkrantz, K
Powell, DH
Woods, JH
Ko, MC
Kennedy, RT
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Pharmacol, Ann Arbor, MI 48109 USA
[3] Univ Florida, Dept Chem, Gainesville, FL 32611 USA
关键词
D O I
10.1002/rcm.1458
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electrospray sample deposition was explored for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). In this method, nanoliter volumes of matrix/analyte mixture were electrosprayed from a high voltage biased (1-2kV) fused-silica capillary onto a grounded MALDI plate mounted 100-500 mum from the capillary outlet. Electrospray deposition with these conditions produced sample spots 200-300 mum in diameter thus matching the laser spot size. Varying spray voltage and distance resulted in different crystal sizes and volatilization rates for 7.-cyano-4-hydroxycinnamic acid matrix. Best results were obtained when the sample was deposited as wet droplets as opposed to deposition as dried solid. Under 'wet-spray' conditions, 2-4 mum diameter crystals were formed and detection limits for several neuropeptides were 0.7-25 amol. Samples could be pre-concentrated on the plate by spraying continuously and allowing sample to evaporate in a small spot. Sample volumes as large as 580 nL were deposited yielding a detection limit of 35 pM for neurotensin 1-11. Electrospray sample deposition yielded similar results when using atmospheric pressure-MALDI coupled with a quadrupole ion trap mass spectrometer, except that the sensitivity was similar toseven-fold worse. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:1193 / 1200
页数:8
相关论文
共 32 条
[1]  
Axelsson J, 1997, RAPID COMMUN MASS SP, V11, P209, DOI 10.1002/(SICI)1097-0231(19970131)11:2<209::AID-RCM734>3.0.CO
[2]  
2-E
[3]   Molecular imaging of biological samples: Localization of peptides and proteins using MALDI-TOF MS [J].
Caprioli, RM ;
Farmer, TB ;
Gile, J .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4751-4760
[4]   An automated noncontact deposition interface for liquid chromatography matrix-assisted laser desorption/ionization mass spectrometry [J].
Ericson, C ;
Phung, QT ;
Horn, DM ;
Peters, EC ;
Fitchett, JR ;
Ficarro, SB ;
Salomon, AR ;
Brill, LM ;
Brock, A .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2309-2315
[5]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[6]   Desorption/ionization on silicon time-of-flight/time-of-flight mass spectrometry [J].
Go, EP ;
Prenni, JE ;
Wei, J ;
Jones, A ;
Hall, SC ;
Witkowska, HE ;
Shen, ZX ;
Siuzdak, G .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2504-2506
[7]  
Gobom J, 1999, J MASS SPECTROM, V34, P105, DOI 10.1002/(SICI)1096-9888(199902)34:2<105::AID-JMS768>3.0.CO
[8]  
2-4
[9]   Investigations of electrospray sample deposition for polymer MALDI mass spectrometry [J].
Hanton, SD ;
Hyder, IZ ;
Stets, JR ;
Owens, KG ;
Blair, WR ;
Guttman, CM ;
Giuseppetti, AA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (02) :168-179
[10]  
Hensel RR, 1997, RAPID COMMUN MASS SP, V11, P1785