NTR calibration in non-linear systems:: different PLS approaches and artificial neural networks

被引:163
作者
Blanco, M [1 ]
Coello, J [1 ]
Iturriaga, H [1 ]
Maspoch, S [1 ]
Pagès, J [1 ]
机构
[1] Univ Autonoma Barcelona, Fac Ciencies, Dept Quim, Unitat Quim Analit, E-08193 Barcelona, Spain
关键词
non-linearity; artificial neural networks; quadratic PLS; NIR; SNV;
D O I
10.1016/S0169-7439(99)00048-9
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The frequent non-linearity of the calibration models used in infrared reflectance spectroscopy (NIRSS) is the main source of large errors in analyte determinations with this technique. Non-linearity in this type of system arises from factors such as the multiplicative effect of differences in particle size among samples or an intrinsically non-linear absorbance-concentration relationship resulting from interactions between components, hydrogen bonding, etc. In this work, calibration methods including partial least-squares (PLS) regression, linear quadratic PLS (LQ-PLS), quadratic PLS (QPLS) and artificial neural networks (ANNs) were used in conjunction with the NIRRS technique to determine the moisture content of acrylic fibres, the wide variability in linear density of which results in differential multiplicative effects among samples. Based on the results, PC-ANN is the best choice for the intended application. However, the joint use of an effective spectral pretreatment and computational methods such as PLS and LQ-PLS, the optimization of which is much less labour-intensive, provides comparable results. Standard normal variate (SNV) was found to be the best of the spectral pretreatments compared with a view to reducing the non-linearity introduced by scattering. The subsequent application of PLS provides accurate results with linear systems (absorption band at 1450 nm). A non-linear calibration model must be applied instead, however, if the system concerned is intrinsically non-linear. Under these conditions, the three methods tested for this purpose (LQ-PLS, QPLS and ANN) provide comparable results. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:75 / 82
页数:8
相关论文
共 18 条
  • [1] STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA
    BARNES, RJ
    DHANOA, MS
    LISTER, SJ
    [J]. APPLIED SPECTROSCOPY, 1989, 43 (05) : 772 - 777
  • [2] ANALYSIS OF COTTON-POLYESTER YARNS BY NEAR-INFRARED REFLECTANCE SPECTROSCOPY
    BLANCO, M
    COELLO, J
    ITURRIAGA, H
    MASPOCH, S
    BERTRAN, E
    [J]. ANALYST, 1994, 119 (08) : 1779 - 1785
  • [3] Effect of data preprocessing methods in near-infrared diffuse reflectance spectroscopy for the determination of the active compound in a pharmaceutical preparation
    Blanco, M
    Coello, J
    Iturriaga, H
    Maspoch, S
    delaPezuela, C
    [J]. APPLIED SPECTROSCOPY, 1997, 51 (02) : 240 - 246
  • [4] Calibration in non-linear near infrared reflectance spectroscopy:: a comparison of several methods
    Blanco, M
    Coello, J
    Iturriaga, H
    Maspoch, S
    Pagès, J
    [J]. ANALYTICA CHIMICA ACTA, 1999, 384 (02) : 207 - 214
  • [5] DAVIES AMC, 1993, NIR NEWS, V4, P10
  • [6] Dhanoa M., 1994, Journal of Near Infrared Spectroscopy, V2, P43, DOI [10.1255/jnirs.30, DOI 10.1255/JNIRS.30]
  • [7] ESBENSEN K, 1987, CHEM INTELL LAB SYST, V2, P37
  • [8] PARTIAL LEAST-SQUARES REGRESSION - A TUTORIAL
    GELADI, P
    KOWALSKI, BR
    [J]. ANALYTICA CHIMICA ACTA, 1986, 185 : 1 - 17
  • [9] GNANADESIKAN R, 1988, METHODS STAT DATA AN
  • [10] PARTIAL LEAST-SQUARES METHODS FOR SPECTRAL ANALYSES .1. RELATION TO OTHER QUANTITATIVE CALIBRATION METHODS AND THE EXTRACTION OF QUALITATIVE INFORMATION
    HAALAND, DM
    THOMAS, EV
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (11) : 1193 - 1202