Variations of uptake rates in benzene diffusive sampling as a function of ambient conditions

被引:27
作者
Ballach, J
Greuter, B
Schultz, E
Jaeschke, W
机构
[1] Deutsch Wetterdienst, Geschaftsfeld Med Meteorol, D-79104 Freiburg, Germany
[2] Univ Frankfurt, Zentrum Umweltforsch, D-60325 Frankfurt, Germany
关键词
diffusive sampler; benzene; ambient conditions; uptake rate; wind-shielded sampling; passive sampling;
D O I
10.1016/S0048-9697(99)00387-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Diffusive samplers have found widespread use as a cost-effective technique in measuring ambient benzene concentrations. In a long-term field study the applicability of thermal desorbable Perkin Elmer (PE) diffusive samplers with Serdolit(R) AD-4 sorbent was tested for weekly integrated benzene measurements. Measuring was carried out under highly differing pollution levels and meteorological conditions. The mean uncertainty range for the benzene concentration interval of 0-18 mu g/m(3) was calculated as 0.3 mu g/m(3). The coefficient of variation was 13%. Including the uncertainty of both the active and the passive technique, it can be interpreted as an upper limit. The detection limit was determined as 0.3 mu g/m(3), providing a technique for monitoring benzene concentrations under rural conditions. The mean experimentally determined uptake rate was 0.34 +/- 0.04 cm(3)/min for shielded sampling in a protective chamber (Sigma-2). The uptake rate had no relationship with air humidity and benzene level. In contrast, a correlation with air temperature was detected. On a weekly basis the seasonal effect of an annual temperature cycle amounted to +/-10% in benzene concentration. A corresponding temperature correction by employing weekly averages reduced the deviation of weekly passive values from active measurement. No influence of ambient air velocity on the uptake rate was found up to a weekly average of 3.5 m/s if an appropriate wind shielding was employed. This was achieved by the original PE-end cap as well as by the Sigma-2 device. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:203 / 217
页数:15
相关论文
共 21 条
[1]  
[Anonymous], 2449 VDI 1
[2]   PERFORMANCE OF THICK-SORBENT DIFFUSIVE SAMPLERS [J].
BARTLEY, DL ;
WOEBKENBERG, ML ;
POSNER, JC .
ANNALS OF OCCUPATIONAL HYGIENE, 1988, 32 (03) :333-343
[3]  
BARTLEY DL, 1983, AM IND HYG ASSOC J, V44, P879
[4]   THE DEVELOPMENT OF AN IMPROVED DIFFUSIVE SAMPLER [J].
BROWN, RH ;
CHARLTON, J ;
SAUNDERS, KJ .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1981, 42 (12) :865-869
[5]   THE USE OF DIFFUSIVE SAMPLERS FOR MONITORING OF AMBIENT AIR [J].
BROWN, RH .
PURE AND APPLIED CHEMISTRY, 1993, 65 (08) :1859-1874
[6]  
*DIN, 1999, DINEN135281
[7]  
*DIN, 1999, DINPREN135283
[8]  
*DIN, 1999, DINEN135282
[9]  
*DIN EN ISO, 1999, 160172 DINEN ISO
[10]  
FUNK W, 1992, QUALITATSSICHERUNG A