Left atrial isthmus: Anatomic aspects relevant for linear catheter ablation procedures in humans

被引:126
作者
Becker, AE [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Cardiovasc Pathol, NL-1105 AZ Amsterdam, Netherlands
关键词
atrial anatomy; atrial arrhythmias; atrial fibrillation; catheter maze;
D O I
10.1046/j.1540-8167.2004.03651.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The success rate of catheter maze ablation procedures for atrial fibrillation depends upon adequate electrical isolation by performing linear ablation lesions. However, recurrence of atrial arrhythmias is not uncommon, particularly in the so-called left atrial isthmus, between the orifice of the left inferior pulmonary vein and the mitral valve annulus. The focus of the present study is the anatomy of this area. Methods and Results: Twenty human hearts were studied. The distance between the left inferior pulmonary vein and the mitral valve, the thickness of the left atrial myocardium, and the extent of left atrial myocardium toward the mitral valve were measured. The AV groove contained a fat pad harboring the great cardiac vein. The distance between the vein and the valve varied considerably (range 17-51 mm). The great cardiac vein coursed along the inferior left atrial wall, approximately 1 cm above the level of the mitral valve. Myocardial thickness also varied considerably (distal: range 1.4-7.7 mm, midway: range 1.2-4.4 mm, proximal: range 0-3.2 mm). Left atrial myocardium extended onto the mitral valve in two hearts, and the left atrial myocardium ended above the level of the mitral valve (range 1.8-5.1 mm) in six hearts. An important variable because it raises the question of how much energy should be used-and at which point-to achieve an adequate transmural ablation line. Conclusion: The great cardiac vein is not an adequate marker for the level of the mitral valve, left atrial myocardium may continue onto the mitral valve, the distance between the left inferior pulmonary vein and mitral valve varies considerably, and left atrial myocardial thickness is highly variable and not uniform.
引用
收藏
页码:809 / 812
页数:4
相关论文
共 9 条
[1]   THE SURGICAL-TREATMENT OF ATRIAL-FIBRILLATION .3. DEVELOPMENT OF A DEFINITIVE SURGICAL-PROCEDURE [J].
COX, JL ;
SCHUESSLER, RB ;
DAGOSTINO, HJ ;
STONE, CM ;
CHANG, BC ;
CAIN, ME ;
CORR, PB ;
BOINEAU, JP .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1991, 101 (04) :569-583
[2]   Modification of the substrate for maintenance of idiopathic human atrial fibrillation -: Efficacy of radiofrequency ablation using nonfluoroscopic catheter guidance [J].
Ernst, S ;
Schlüter, M ;
Ouyang, F ;
Khanedani, A ;
Cappato, R ;
Hebe, J ;
Volkmer, M ;
Antz, M ;
Kuck, KH .
CIRCULATION, 1999, 100 (20) :2085-2092
[3]   Right and left atrial radiofrequency catheter therapy of paroxysmal atrial fibrillation [J].
Haissaguerre, M ;
Jais, P ;
Shah, DC ;
Gencel, L ;
Pradeau, V ;
Garrigues, S ;
Chouairi, S ;
Hocini, M ;
LeMetayer, P ;
Roudaut, R ;
Clementy, J .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (12) :1132-1144
[4]  
Jaïs P, 1999, AM J CARDIOL, V84, p139R
[5]   Mapping and ablation of left atrial flutters [J].
Jaïs, P ;
Shah, DC ;
Haïssaguerre, M ;
Hocini, M ;
Peng, JT ;
Takahashi, A ;
Garrigue, S ;
Le Métayer, P ;
Clémenty, J .
CIRCULATION, 2000, 101 (25) :2928-2934
[6]  
LUDINGHAUSEN M, 1992, CLIN ANAT, V5, P1
[7]   Characterization of reentrant circuits in left atrial macroreentrant tachycardia -: Critical isthmus block can prevent atrial tachycardia recurrence [J].
Ouyang, FF ;
Ernst, S ;
Vogtmann, T ;
Goya, M ;
Volkmer, M ;
Schaumann, A ;
Bänsch, D ;
Antz, M ;
Kuck, KH .
CIRCULATION, 2002, 105 (16) :1934-1942
[8]   Catheter ablation of paroxysmal atrial fibrillation using a 3D mapping system [J].
Pappone, C ;
Oreto, G ;
Lamberti, F ;
Vicedomini, G ;
Loricchio, ML ;
Shpun, S ;
Rillo, M ;
Calabrò, MP ;
Conversano, A ;
Ben-Haim, SA ;
Cappato, R ;
Chierchia, S .
CIRCULATION, 1999, 100 (11) :1203-1208
[9]  
REISS P, 1981, ANAT CLIN, V2, P369