UV disinfection of treated wastewater in a large-scale pilot plant and inactivation of selected bacteria in a laboratory UV device

被引:126
作者
Hassen, A
Mahrouk, M
Ouzari, H
Cherif, M
Boudabous, A
Damelincourt, JJ
机构
[1] Inst Natl Rech Sci & Tech, Lab Environm, Tunis, Tunisia
[2] Fac Sci Tunis, Microbiol Lab, Tunis 1060, Tunisia
[3] Univ Toulouse 3, Ctr Phys Plasmas & Applicat Toulouse, F-31062 Toulouse, France
关键词
UV irradiation; wastewater; indicator bacteria; modelling; kinetics; photoreactivation;
D O I
10.1016/S0960-8524(99)00179-0
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Efficiency of UV disinfection of unfiltered and filtered secondary wastewater effluent, using a large-scale pilot system, and the inactivation of six bacterial species in a laboratory UV-device have been studied. Pilot plant studies revealed low levels of coliforms and streptococci (3 logarithmic units reduction) when a wastewater UV transmission of 45% and an average effective UV dose of 100 mW a cm(-2) were used. By contrast, removal of Pseudomonas aeruginosa appeared insufficient (<1.1 logarithmic units). Laboratory investigations, using the six bacterial species as reference, showed that the kinetics of bacterial removal agreed with the model of Chick-Watson, which is formulated by the equation dN/dt = -k'(CN)-N-n. It also appeared, that according to the UV dose applied, two types of inactivation prevailed: a high rate of inactivation, with weak UV doses, and a low rate of inactivation with relatively high doses. Each examined strain was characterised by two K coefficients, (K-1 and K-2). Lower the K value, more the bacterial resistance to UV. Hierarchical classification of bacteria, based on the values of kinetic constants, revealed three groups of different sensitivity to UV. A resistant group, represented by the two strains of P. aeruginosa ATCC 15442 and Bacillus subtilis 6633, and a sensitive group, with the strain of Escherichia coli ATCC 11229. A medium group was represented by Enterococcus ATCC 19433, Serratia marcescens ATCC 8100 and P. aeruginosa S21. Kinetic studies revealed that the first instants of exposure (2-10 s) to a UV intensity of 5-8 mW cm(-2) appeared as deciding factors in the disinfection with UV irradiation. The importance of cumulative UV dose was only secondary. Photoreactivation of micro-organisms following UV disinfection was observed with all bacterial strains studied here, except for P. aeruginosa ATCC 15442, P. aeruginosa ATCC 15442 mutant mt and Enterococcus hirac ATCC 10541. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:141 / 150
页数:10
相关论文
共 37 条
[1]  
ALLANI M, 1993, THESIS U PARIS 7
[2]   Ultraviolet irradiation and chlorination dechlorination for municipal wastewater disinfection: Assessment of performance limitations [J].
Blatchley, ER ;
Bastian, KC ;
Duggirala, RK ;
Alleman, JE ;
Moore, M ;
Schuerch, P .
WATER ENVIRONMENT RESEARCH, 1996, 68 (02) :194-204
[3]   BIOASSAY FOR FULL-SCALE UV DISINFECTION SYSTEMS [J].
BLATCHLEY, ER ;
HUNT, BA .
WATER SCIENCE AND TECHNOLOGY, 1994, 30 (04) :115-123
[4]  
Carrigan P., 1991, WATER CONDITIONING P, V33, P43
[5]  
DAMELINCOURT JJ, 1998, INT C WAT MED COLL E
[6]  
Failly J., 1994, EAU IND NUISANCES, V32, P58
[7]   DISINFECTION UNDER DYNAMIC CONDITIONS - MODIFICATION OF HOM MODEL FOR DECAY [J].
HAAS, CN ;
JOFFE, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1994, 28 (07) :1367-1369
[8]  
Haas CN, 1990, HDB COMMUNITY WATER
[9]   ULTRAVIOLET INACTIVATION OF SELECTED BACTERIA AND VIRUSES WITH PHOTOREACTIVATION OF THE BACTERIA [J].
HARRIS, GD ;
ADAMS, VD ;
SORENSEN, DL ;
CURTIS, MS .
WATER RESEARCH, 1987, 21 (06) :687-692
[10]  
HOM LW, 1972, J SANIT ENG DIV ASCE, V98, P183