Inappropriate therapy from atrial fibrillation and sinus tachycardia in automated implantable cardioverter defibrillators

被引:36
作者
Nanthakumar, K
Paquette, M
Newman, D
Deno, DC
Malden, L
Gunderson, B
Gilkerson, J
Greene, M
Heng, D
Dorian, P
机构
[1] St Michaels Hosp, Div Cardiol, Toronto, ON M5B 1W8, Canada
[2] Intermed Inc, Angleton, TX USA
[3] St Jude Ventritex Inc, Sunnyvale, CA USA
[4] Medtronic Inc, Minneapolis, MN USA
[5] Guidant Inc, St Paul, MN USA
关键词
D O I
10.1016/S0002-8703(00)90010-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Inappropriate therapy from supraventricular tachyarrhythmias (atrial fibrillation [AF] and sinus tachycardia [ST]) in patients with implanted cardioverter defibrillators is a major challenge. We tested the performance of stability algorithms from 3 manufacturers for episodes of inappropriate therapy delivered because of AF and an onset algorithm for all episodes of inappropriate therapy caused by ST. Methods Therapy was classified as caused by ventricular tachycardia (VT), ST, or AF from review of stored intracardiac electrograms, history, clinical information, and R-R data before study inception. By using 30 to 60 R-R intervals before therapy, sensitivity and specificity for a family of stability values and percentage of onset values were calculated for each manufacturer and receiver operating characteristic curves generated. Results of the 217 patients monitored, 62 (29%) received inappropriate therapy, and 40 had complete R-R information available. Of the 40 patients, 21 patients received therapy for AF, 19 for ST, and 1 patient for noise; 15 (38%) also received appropriate therapy for VT. We analyzed 83 episodes of VT from 18 patients, 94 episodes of AF from 21 patients, and 56 episodes of ST from 19 patients. Specificity, in the clinically relevant sensitivity range of greater than or equal to 95%, was comparable across manufacturers at about 40%. An onset value of 80% was associated with 91% sensitivity and 95% specificity for the specific algorithm tested. Conclusions Inappropriate therapy is a common problem in implantable cardiac defibrillators. The performance of the stability algorithms used to differentiate AF from VT was less than ideal, though comparable across manufacturers. The onset algorithm accurately differentiates ST From VT.
引用
收藏
页码:797 / 803
页数:7
相关论文
共 24 条
[1]   Performance of basic ventricular tachycardia detection algorithms in implantable cardioverter defibrillators: Implications for device programming [J].
Anderson, MH ;
Murgatroyd, FD ;
Hnatkova, K ;
Xie, BY ;
Jones, S ;
Rowland, E ;
Ward, DE ;
Camm, AJ ;
Malik, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (12) :2975-2983
[2]   CLINICAL-EXPERIENCE WITH A TIERED-THERAPY, MULTIPROGRAMMABLE ANTIARRHYTHMIA DEVICE [J].
BARDY, GH ;
TROUTMAN, C ;
POOLE, JE ;
KUDENCHUK, PJ ;
DOLACK, GL ;
JOHNSON, G ;
HOFER, B .
CIRCULATION, 1992, 85 (05) :1689-1698
[3]   IMPLANTABLE TRANSVENOUS CARDIOVERTER-DEFIBRILLATORS [J].
BARDY, GH ;
HOFER, B ;
JOHNSON, G ;
KUDENCHUK, PJ ;
POOLE, JE ;
DOLACK, GL ;
GLEVA, M ;
MITCHELL, R ;
KELSO, D .
CIRCULATION, 1993, 87 (04) :1152-1168
[4]   Prospective evaluation of new and old criteria to discriminate between supraventricular and ventricular tachycardia in implantable defibrillators [J].
Barold, HS ;
Newby, KH ;
Tomassoni, G ;
Kearney, M ;
Brandon, J ;
Natale, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (07) :1347-1355
[5]   ACUTE EFFICACY AND CHRONIC FOLLOW-UP OF PATIENTS WITH NON-THORACOTOMY 3RD GENERATION IMPLANTABLE DEFIBRILLATORS [J].
BRACHMANN, J ;
STERNS, LD ;
HILBEL, T ;
SCHOELS, W ;
BEYER, T ;
MEHMANESH, H ;
LANGE, R ;
RUFRICHTER, J ;
KRAFT, P ;
HAGL, S ;
KUBLER, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (03) :499-505
[6]  
Brugada J, 1999, AM J CARDIOL, V83, p40D
[7]  
*CEDERS INV, 1993, J AM COLL CARDIOL, V21, pA278
[8]  
Dorian P, 1999, CIRCULATION, V100, P786
[9]   ACTUARIAL INCIDENCE AND PATTERN OF OCCURRENCE OF SHOCKS FOLLOWING IMPLANTATION OF THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR [J].
FOGOROS, RN ;
ELSON, JJ ;
BONNET, CA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (09) :1465-1473
[10]  
FROMER M, 1987, PACE, V10, P593