The influence of positioning on spectroscopic measurements of brain oxygenation

被引:30
作者
Fuchs, G [1 ]
Schwarz, G [1 ]
Kulier, A [1 ]
Litscher, G [1 ]
机构
[1] Graz Univ, Dept Anesthesiol & Intens Care Med, A-8036 Graz, Austria
关键词
near-infrared spectroscopy; cerebral regional oxygen saturation; operating position; neurosurgery; sevoflurane;
D O I
10.1097/00008506-200004000-00001
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This study was designed to evaluate the influence of body position during neurosurgical and cerebrovascular operations on regional cerebral oxygen saturation (rSO(2)). Awake volunteers (group I; n = 14), anesthetized patients (group II; n = 48) undergoing lumbar discectomy, and 12 patients undergoing carotid endarterectomy (group III) with internal carotid artery (ICA) stenosis were studied. Anesthesia in the patient groups was performed with sevoflurane (1.1 Vol% insp.) in N2O2/O-2 mixture (FiO(2) 0.4) rSO(2) was monitored with a INVOS 4100 cerebral oxymeter (Somanetics Corporation, Troy, MI). Measurements were done in all groups in supine position with head turned to the right and left side. Furthermore, in groups I and II, rSO(2) was measured in right lateral, left lateral, prone, or sitting position. In each position the parameters were registered at three times (1, 3, and 5 min after taking up the position). In the healthy volunteers, the mean rSO(2) values of both hemispheres were 71.3 +/- 5.0%. No significant changes of rSO(2) were found interhemispherical and upon turning the head to both sides or positioning to the prone and both lateral positions. After assuming the sitting position, the decrease of rSO(2) was not significant. In group II, rSO(2) decreased significantly in the sitting position. In group III, baseline readings for rSO(2) obtained from the side of ICA stenosis were significantly lower, compared to the contralateral side. After turning the head to the ipsilateral side, this difference diminished. In contrast, turning the head toward the contralateral side, the rSO(2) difference remained nearly constant, both values decreasing constantly throughout the observation period. In conclusion, after different positioning maneuvers awake and under anesthesia, alterations of rSO(2) can be registrated by near-infrared spectroscopy (NIRS).
引用
收藏
页码:75 / 80
页数:6
相关论文
共 42 条
[1]  
ABBUSHI W, 1980, ANAESTHESIST, V29, P521
[2]  
BENUMOF JL, 1983, THORACIC ANESTHESIA, V8, P287
[3]   THE EFFECT OF BODY POSITION ON THE CIRCULATION AT REST AND DURING EXERCISE, WITH SPECIAL REFERENCE TO THE INFLUENCE ON THE STROKE VOLUME [J].
BEVEGARD, S ;
HOLMGREN, A ;
JONSSON, B .
ACTA PHYSIOLOGICA SCANDINAVICA, 1960, 49 (2-3) :279-298
[4]   THE ROLE OF ATLANTOID COMPRESSION IN THE ETIOLOGY OF INTERNAL CAROTID THROMBOSIS [J].
BOLDREY, E ;
MAASS, L ;
MILLER, E .
JOURNAL OF NEUROSURGERY, 1956, 13 (02) :127-139
[5]  
BRITT B A, 1964, Can Anaesth Soc J, V11, P514, DOI 10.1007/BF03005094
[6]   ANEMIA AND HYPOTENSION AS CONTRIBUTORS TO PERIOPERATIVE LOSS OF VISION [J].
BROWN, RH ;
SCHAUBLE, JF ;
MILLER, NR .
ANESTHESIOLOGY, 1994, 80 (01) :222-226
[7]   CARDIORESPIRATORY EFFECTS OF CHANGE OF BODY POSITION [J].
COONAN, TJ ;
HOPE, CE .
CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1983, 30 (04) :424-437
[8]  
COURINGTON FW, 1968, CLIN ANESTH, V3, P23
[9]   ESTIMATION OF OPTICAL PATHLENGTH THROUGH TISSUE FROM DIRECT TIME OF FLIGHT MEASUREMENT [J].
DELPY, DT ;
COPE, M ;
VANDERZEE, P ;
ARRIDGE, S ;
WRAY, S ;
WYATT, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (12) :1433-1442
[10]   CEREBRAL OXIMETRY - A USEFUL MONITOR DURING CAROTID-ARTERY SURGERY [J].
DUNCAN, LA ;
RUCKLEY, CV ;
WILDSMITH, JAW .
ANAESTHESIA, 1995, 50 (12) :1041-1045