Accelerated time-resolved 3D contrast-enhanced MR angiography at 3T: clinical experience in 31 patients

被引:21
作者
Frydrychowicz, Alex
Bley, Thorsten A.
Winterer, Jan T.
Harloff, Andreas
Langer, Mathias
Hennig, Juergen
Markl, Michael
机构
[1] Univ Hosp Freiberg, Dept Diagnost Radiol & Med Phys, D-79106 Freiburg, Germany
[2] Univ Hosp Freiberg, Dept Neurol & Clin Neurophysiol, D-79106 Freiburg, Germany
关键词
magnetic resonance angiography; cardiovascular system; arteries; thoracic arteries; veins; 3T;
D O I
10.1007/s10334-006-0046-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate whether time-resolved 3D MR-angiography at 3T with a net acceleration factor of eight is applicable in clinical routine and to evaluate whether good image quality and a low artifact level can be achieved with a temporal update rate that allows for additional information on pathologies. Materials and methods: Thirty-one consecutive patients underwent time-resolved 3D contrast-enhanced MR-angiography on a 3T system. Imaging consisted of accelerated 3D gradient echo sequences combining parallel imaging with an acceleration factor of four, partial Fourier acquisition along phase and slice encoding direction, and twofold temporal acceleration using view sharing. Data volumes representing the arterial and venous contrast phases were independently evaluated by two experienced radiologists by grading of image quality and artifact level on a 0-3 scale. Results: Time-resolved MR-angiography was successfully performed in all subjects without the need for contrast agent bolus timing. Excellent arterial (average score = 2.65 +/- 0.32) and good venous (average score = 2.56 +/- 0.28) diagnostic image quality and little image degrading due to artifacts (average score = 2.20 +/- 0.16) were confirmed by both independent readers (agreement in 65.2% of all evaluations). In 14 patients vascular pathologies were identified in the arterial phases. In eight examinations temporal resolution and depiction of contrast agent dynamics provided additional information about pathology. Discussion: Without the necessity for additional bolus timing, time-resolved 3D contrast-enhanced MR-angiography with imaging acceleration along both the spatial encoding direction and temporal domain revealed excellent diagnostic image quality in neurovascular and thoracic imaging. Despite the limited spatial resolution as compared to high-resolution imaging of the carotid artery bifurcation, the results demonstrate the applicability of contrast-enhanced MR-angiography in thoracic and abdominal MRA as well as cervical imaging with a temporal update rate allowing for additional information on pathologies. Future studies may include an evaluation of optimal trade-offs between spatial and temporal resolution, different acceleration factors and a comparison to the gold-standard for accuracy.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 33 条
[1]   Contrast-enhanced peripheral magnetic resonance angiography using time-resolved vastly undersampled isotropic projection reconstruction [J].
Du, J ;
Carroll, TJ ;
Brodsky, E ;
Lu, AM ;
Grist, TM ;
Mistretta, CA ;
Block, WF .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) :894-900
[2]   Cerebral arteriovenous malformations: morphologic evaluation by ultrashort 3D gadolinium-enhanced MR angiography [J].
Duran, M ;
Schoenberg, SO ;
Yuh, WTC ;
Knopp, MV ;
van Kaick, G ;
Essig, M .
EUROPEAN RADIOLOGY, 2002, 12 (12) :2957-2964
[3]   Whole-body MR angiography using a novel 32-receiving-channel MR system with surface coil technology: First clinical experience [J].
Fenchel, M ;
Requardt, M ;
Tomaschko, K ;
Kramer, U ;
Stauder, NI ;
Naegele, T ;
Schlemmer, HP ;
Claussen, CD ;
Miller, S .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (05) :596-603
[4]   Time-resolved echo-shared parallel MRA of the lung: observer preference study of image quality in comparison with non-echo-shared sequences [J].
Fink, C ;
Puderbach, M ;
Ley, S ;
Zaporozhan, J ;
Plathow, C ;
Kauczor, HU .
EUROPEAN RADIOLOGY, 2005, 15 (10) :2070-2074
[5]  
Fink C, 2005, INVEST RADIOL, V40, P40
[6]   Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography [J].
Foo, TKF ;
Saranathan, M ;
Prince, MR ;
Chenevert, TL .
RADIOLOGY, 1997, 203 (01) :275-280
[7]  
Goldfarb JW, 2000, J MAGN RESON IMAGING, V11, P201, DOI 10.1002/(SICI)1522-2586(200002)11:2<201::AID-JMRI19>3.0.CO
[8]  
2-4
[9]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[10]   Combination of 2D sensitivity encoding and 2D partial Fourier techniques for improved acceleration in 3D contrast-enhanced MR angiography [J].
Hu, HCH ;
Madhuranthakam, AJ ;
Kruger, DG ;
Glockner, JF ;
Riederer, SJ .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (01) :16-22