Nitric oxide monitoring in brain extracellular fluid: characterisation of Nafion®-modified Pt electrodes in vitro and in vivo

被引:43
作者
Brown, Finbar O.
Finnerty, Niall J.
Lowry, John P. [1 ]
机构
[1] Natl Univ Ireland, Dept Chem, BioAnalyt Lab, Sensors Dev Unit, Maynooth, Kildare, Ireland
基金
爱尔兰科学基金会; 英国工程与自然科学研究理事会;
关键词
CARBON-FIBER MICROELECTRODES; MODIFIED POLY(PHENYLENEDIAMINE)-COATED ELECTRODES; PARAMAGNETIC-RESONANCE SPECTROSCOPY; PERFLUOROSULFONATED IONOMER FILMS; GLUCOSE-OXIDASE; BIOLOGICAL-SYSTEMS; PASTE ELECTRODES; GLASSY-CARBON; ASCORBIC-ACID; RAT-BRAIN;
D O I
10.1039/b909005c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A Nafion (R)(5 pre-coats/2 dip-coats)-modified Pt sensor developed for real-time neurochemical monitoring has now been characterised in vitro for the sensitive and selective detection of nitric oxide (NO). A potentiodynamic profile at bare Pt established +0.9 V (vs. SCE) to be the most appropriate applied potential for NO oxidation. The latter was confirmed using oxyhaemoglobin and N-2, both of which reduced the NO signal to baseline levels. Results indicated enhanced NO sensitivity at the Nafion (R)(5/2)sensor (1.67 +/- 0.08 nA mu M-1) compared to bare Pt (1.08 +/- 0.20 nA mu M-1) and negligible interference from a wide range of endogenous electroactive interferents such as ascorbic acid, dopamine and its metabolites, NO2- and H2O2. The response time of 33.7 +/- 2.7 s was found to improve (19.0 +/- 3.4 s) when the number of Nafion (R) layers was reduced to 2/1 and an insulating outer layer of poly(o-phenylenediamine) added. When tested under physiological conditions of 37 degrees C the response time of the Nafion (R)(5/2) sensor improved to 14.00 +/- 2.52 s. In addition, the NO response was not affected by physiological concentrations of O-2 despite the high reactivity of the two species for each other. The limit of detection (LOD) was estimated to be 5 nM while stability tests in lipid (phosphatidylethanolamine; PEA) and protein (bovine serum albumin; BSA) solutions (10%) found an initial ca. 38% drop in sensitivity in the first 24 h which remained constant thereafter. Preliminary in vivo experiments involving systemic administration of NO and L-arginine produced increases in the signals recorded at the Nafion (R)(5/2) sensor implanted in the striatum of freely-moving rats, thus supporting reliable in vivo recording of NO.
引用
收藏
页码:2012 / 2020
页数:9
相关论文
共 116 条
[1]   Continuous monitoring of amino acids and related compounds with poly(3-methylthiophene)-coated cylindrical carbon fiber microelectrodes [J].
Agüí, L ;
González-Cortés, A ;
Yáñez-Sedeño, P ;
Pingarrón, JM .
ANALYTICA CHIMICA ACTA, 1999, 401 (1-2) :145-154
[2]   Amperometric glutamate biosensor based on poly(o-phenylenediamine) film electrogenerated onto modified carbon paste electrodes [J].
Alvarez-Crespo, SL ;
Lobo-Castanon, MJ ;
Miranda-Ordieres, AJ ;
Tunon-Blanco, P .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (08) :739-747
[3]   MEASUREMENT OF NITRIC-OXIDE IN BIOLOGICAL MODELS [J].
ARCHER, S .
FASEB JOURNAL, 1993, 7 (02) :349-360
[4]   Practical aspects and methodological approaches to achieve electrochemical detection of submicromolar NO in biological systems [J].
Bedioui, F ;
Trevin, S .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (02) :227-230
[5]   Elaboration and use of nickel planar macrocyclic complex-based sensors for the direct electrochemical measurement of nitric oxide in biological media [J].
Bedioui, F ;
Trevin, S ;
Devynck, J ;
Lantoine, F ;
Brunet, A ;
Devynck, MA .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (03) :205-212
[6]   Chemically modified microelectrodes designed for the electrochemical determination of nitric oxide in biological systems [J].
Bedioui, F ;
Trevin, S ;
Devynck, J .
ELECTROANALYSIS, 1996, 8 (12) :1085-1091
[7]   Fabrication and physico-chemical properties of Nafion Langmuir-Schaefer films [J].
Bertoncello, P ;
Ram, MK ;
Notargiacomo, A ;
Ugo, P ;
Nicolini, C .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2002, 4 (16) :4036-4043
[8]   Calibration of NO sensors for in-vivo voltammetry: laboratory synthesis of NO and the use of UV-visible spectroscopy for determining stock concentrations [J].
Brown, FO ;
Finnerty, NJ ;
Bolger, FB ;
Millar, J ;
Lowry, JP .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (04) :964-971
[9]   Microelectrochemical sensors for in vivo brain analysis:: an investigation of procedures for modifying Pt electrodes using Nafion® [J].
Brown, FO ;
Lowry, JP .
ANALYST, 2003, 128 (06) :700-705
[10]   Voltammetric detection of nitric oxide (NO) in the rat brain: Its variations throughout the sleep-wake cycle [J].
Burlet, S ;
Cespuglio, R .
NEUROSCIENCE LETTERS, 1997, 226 (02) :131-135