Biomechanical analysis of an interbody cage with three integrated cancellous lag screws in a two-level cervical spine fusion construct: an in vitro study

被引:39
作者
Nayak, Aniruddh N. [1 ]
Stein, Matthew I. [2 ]
James, Chris R. [1 ]
Gaskins, Roger B., III [2 ]
Cabezas, Andres F. [1 ]
Adu-Lartey, Maxwell [3 ]
Castellvi, Antonio E. [3 ]
Santoni, Brandon G. [1 ,2 ]
机构
[1] Fdn Orthopaed Res & Educ, Phillip Spiegel Orthopaed Res Lab, Tampa, FL 33637 USA
[2] Univ S Florida, Dept Orthopaed & Sports Med, Tampa, FL 33612 USA
[3] Florida Orthopaed Inst, Ctr Spinal Disorders, Tampa, FL 33637 USA
关键词
No-profile interbody device; Anterior locking plate; ACDF; Biomechanics; Cervical spine; Multi-level cervical arthrodesis; Integrated screws; PHARYNX/ESOPHAGUS RETRACTION; INTRAOPERATIVE MEASUREMENT; DISKECTOMY; SURGERY; PLATE; DYSPHAGIA; DEVICE; SPACER;
D O I
10.1016/j.spinee.2014.06.011
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
BACKGROUND CONTEXT: Despite an increase in the clinical use of no-profile anchored interbody cages (AIC) for anterior cervical discectomy and fusion (ACDF) procedures, there is little published biomechanical data describing its stabilizing effect relative to the traditional anterior plating technique over two contiguous levels. PURPOSE: To biomechanically compare the acute stability conferred by a stand-alone interbody fusion device with three integrated fixation screws ("anchored cage") with a traditional six-hole rigid anterior plate in a two contiguous levels (C4-C5+C5-C6) fusion construct. We hypothesized that the anchored cage would confer comparable segmental rigidity to the cage and anterior plate construct. STUDY DESIGN: A biomechanical laboratory study using cadaveric human cervical spines. METHODS: Seven (n=7) cadaveric human cervical spines (C3-C7) were subjected to quasistatic, pure-moment loading (+/- 1.5 Nm) in flexion-extension (flex/ext), right/left lateral bending (RB/LB), and right/left axial rotation (RR/LR) for the following test conditions: intact; after discectomy and insertion of the AIC at C4-C5 and C5-C6 with anchoring screws engaged; after the removal of the integrated anchoring screws and instrumentation of an anterior locking plate (ALP) over both levels; and cage-only (CO) configuration with screws and anterior plate removed. Intervertebral range of motion (ROM) at the instrumented levels was the primary biomechanical outcome. RESULTS: Flex/ext, RB/LB, and RR/LR ROMs were significantly reduced (p<.001) over both levels by AIC and ALP constructs relative to the CO construct. Significant reduction in flex/ext motion was achieved with the ALP (6.8 +/- 3.7) relative to the AIC (10.2 degrees +/- 64.6 degrees) (p=.041) construct. No significant differences were seen in ROM reductions over the two levels between the AIC and APL groups in lateral bending or axial rotation (p>.826). CONCLUSIONS: The anchored cage fusion construct conferred similar acute biomechanical stability in lateral bending and axial rotation ROMs relative to rigid anterior plating. We identified a statistically significant reduction (Delta=3.4 degrees, combined over two levels) in sagittal plane ROM conferred by the ALP relative to the AIC construct. Our biomechanical findings may support the clinical use of no-profile integrated interbody devices over two contiguous levels in ACDF. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:3002 / 3010
页数:9
相关论文
共 26 条
[1]
Incidence of dysphagia after anterior cervical spine surgery - A prospective study [J].
Bazaz, R ;
Lee, MJ ;
Yoo, JU .
SPINE, 2002, 27 (22) :2453-2458
[2]
Anterior cervical interbody fusion using autogeneic and allogeneic bone graft substrate: A prospective comparative analysis [J].
Bishop, RC ;
Moore, KA ;
Hadley, MN .
JOURNAL OF NEUROSURGERY, 1996, 85 (02) :206-210
[3]
Outcome analysis of noninstrumented anterior cervical discectomy and interbody fusion in 348 patients [J].
Cauthen, JC ;
Kinard, RE ;
Vogler, JB ;
Jackson, DE ;
DePaz, OB ;
Hunter, OL ;
Wasserburger, LB ;
Williams, VM .
SPINE, 1998, 23 (02) :188-192
[4]
The biomechanical stability of a novel spacer with integrated plate in contiguous two-level and three-level ACDF models: an in vitro cadaveric study [J].
Clavenna, Andrew L. ;
Beutler, William J. ;
Gudipally, Manasa ;
Moldavsky, Mark ;
Khalil, Saif .
SPINE JOURNAL, 2012, 12 (02) :157-163
[5]
Adverse Events Associated With Anterior Cervical Spine Surgery [J].
Daniels, Alan H. ;
Riew, K. Daniel ;
Yoo, J. U. ;
Ching, Alexander ;
Birchard, Keith R. ;
Kranenburg, Andy J. ;
Hart, Robert A. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2008, 16 (12) :729-738
[6]
Anterior cervical Discectomy and fusion associated complications [J].
Fountas, Kostas N. ;
Kapsalaki, Eftychia Z. ;
Nikolakakos, Leonidas G. ;
Smisson, Hugh F. ;
Johnston, Kim W. ;
Grigorian, Arthur A. ;
Lee, Gregory P. ;
Robinson, Joe S. .
SPINE, 2007, 32 (21) :2310-2317
[7]
Intraoperative measurement of pharynx/esophagus retraction during anterior cervical surgery.: Part I:: pressure [J].
Heese, Oliver ;
Schroeder, Frank ;
Westphal, Manfred ;
Papavero, Luca .
EUROPEAN SPINE JOURNAL, 2006, 15 (12) :1833-1837
[8]
Hilibrand Alan S, 2004, Spine J, V4, p190S, DOI 10.1016/j.spinee.2004.07.007
[9]
Ishihara Hirokazu, 2004, Spine J, V4, P624, DOI 10.1016/j.spinee.2004.04.011
[10]
Ji GY, 2013, J SPINAL DISORD TECH