Assessing the capabilities of a 4kx4k CCD camera for electron cryo-microscopy at 300kV

被引:26
作者
Booth, Christopher R.
Jakana, Joanita
Chiu, Wah [1 ]
机构
[1] Baylor Coll Med, Natl Ctr Macromol Imaging, Houston, TX 77030 USA
[2] Baylor Coll Med, Program Struct & Computat Biol & Mol Biophys, Houston, TX 77030 USA
关键词
cryo-EM; CCD camera; 300; kV; electron cryo-microscopy;
D O I
10.1016/j.jsb.2006.08.019
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
CCD cameras have numerous advantages over photographic film for detecting electrons; however the point spread function of these cameras has not been sufficient for single particle data collection to subnanometer resolution with 300 kV microscopes. We have adopted spectral signal to noise ratio (SNR) as a parameter for assessing detector quality for single particle imaging. The robustness of this parameter is confirmed under a variety of experimental conditions. Using this parameter, we demonstrate that the SNR of images of either amorphous carbon film or ice embedded virus particles collected on a new commercially available 4kx4k CCD camera are slightly better than photographic film at low spatial frequency (< 1/5 Nyquist frequency), and as good as photographic film out to half of the Nyquist frequency. In addition it is slightly easier to visualize ice embedded particles on this CCD camera than on photographic film. Based on this analysis it is realistic to collect images containing subnanometer resolution data (6-9 angstrom) using this CCD camera at an effective magnification of similar to 112000 x on a 300 kV electron microscope. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:556 / 563
页数:8
相关论文
共 20 条
[1]   A 9 Å single particle reconstruction from CCD captured images on a 200 kV electron cryomicroscope [J].
Booth, CR ;
Jiang, W ;
Baker, ML ;
Zhou, ZH ;
Ludtke, SJ ;
Chiu, W .
JOURNAL OF STRUCTURAL BIOLOGY, 2004, 147 (02) :116-127
[2]  
CHENG A, 2006, J STRUCT BIOL
[3]   Electron cryomicroscopy of biological machines at subnanometer resolution [J].
Chiu, W ;
Baker, ML ;
Jiang, W ;
Dougherty, M ;
Schmid, MF .
STRUCTURE, 2005, 13 (03) :363-372
[4]  
CHIU W, 2006, JEOL NEWS, V41, P12
[5]   METHODS TO MEASURE PROPERTIES OF SLOW-SCAN CCD CAMERAS FOR ELECTRON DETECTION [J].
DERUIJTER, WJ ;
WEISS, JK .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10) :4314-4321
[6]   Performance of a 2k CCD camera designed for electron crystallography at 400 kV [J].
Downing, KH ;
Hendrickson, FM .
ULTRAMICROSCOPY, 1999, 75 (04) :215-233
[7]   CCD detectors in high-resolution biological electron microscopy [J].
Faruqi, AR ;
Subramaniam, S .
QUARTERLY REVIEWS OF BIOPHYSICS, 2000, 33 (01) :1-27
[8]  
Janesick J. R., 2001, SCI CHARGE COUPLED D
[9]   The pore structure of the closed RyR1 channel [J].
Ludtke, SJ ;
Serysheva, II ;
Hamilton, SL ;
Chiu, W .
STRUCTURE, 2005, 13 (08) :1203-1211
[10]   Object oriented database and electronic notebook for transmission electron microscopy [J].
Ludtke, SJ ;
Nason, L ;
Tu, H ;
Peng, LW ;
Chiu, W .
MICROSCOPY AND MICROANALYSIS, 2003, 9 (06) :556-565