CT-derived estimation of cochlear morphology and electrode array position in relation to word recognition in nucleus-22 recipients

被引:181
作者
Skinner, MW
Ketten, DR
Holden, LK
Harding, GW
Smith, PG
Gates, GA
Neely, JG
Kletzker, GR
Brunsden, B
Blocker, B
机构
[1] Washington Univ, Sch Med, Dept Otolaryngol Head & Neck Surg, St Louis, MO 63110 USA
[2] Harvard Univ, Sch Med, Dept Otol & Laryngol, Boston, MA 02114 USA
[3] Woods Hole Oceanog Inst, Dept Biol, Woods Hole, MA 02548 USA
[4] Univ Washington, Virginia Merrill Bloedel Hearing Res Ctr, Seattle, WA 98195 USA
[5] Washington Univ, Dept Radiol, Sch Med, St Louis, MO 63110 USA
来源
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY | 2002年 / 3卷 / 03期
关键词
cochlear length; cochlear implant; electrode array; computed tomography (CT); two- and three-dimensional reconstruction; word recognition;
D O I
10.1007/s101620020013
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This study extended the findings of Ketten et al. [Ann. Otol. Rhinol. Laryngol. Suppl. 175:1-16 (1998)] by estimating the three-dimensional (3D) cochlear lengths, electrode array intracochlear insertion depths, and characteristic frequency ranges for 13 more Nucleus-22 implant recipients based on in vivo computed tomography (CT) scans. Array insertion depths were correlated with NU-6 word scores (obtained one year after SPEAK strategy use) by these patients and the 13 who used the SPEAK strategy from the Ketten et al. study. For these 26 patients, the range of cochlear lengths was 29.1-37.4 mm. Array insertion depth range was 11.9-25.9 mm, and array insertion depth estimated from the surgeon's report was 1.14 mm longer than CT-based estimates. Given the assumption that the human hearing range is fixed (2020,000 Hz) regardless of cochlear length, characteristic frequencies at the most apical electrode (estimated with Greenwood's equation [Greenwood DD (1990) A cochlear frequency - position function of several species - 29 years later. J Acoust. Soc. Am. 33: 1344-1356] and a patient-specific constant a,) ranged from 308 to 3674 Hz. Patients' NU-6 word scores were significantly correlated with insertion depth as a percentage of total cochlear length (R = 0.452; r(2) = 0.204; p = 0.020), suggesting that part of the variability in word recognition across implant recipients can be accounted for by the position of the electrode array in the cochlea. However, NU-6 scores ranged from 4% to 81% correct for patients with array insertion depths between 4% and 68% of total cochlear length. Lower scores appeared related to low spiral ganglion cell survival (e.g., lues), aberrant current paths that produced facial nerve stimulation by apical electrodes (i.e., otosclerosis), central auditory processing difficulty, below-average verbal abilities, and early Alzheimer's disease. Higher scores appeared related to patients' high-average to above-average verbal abilities. Because most patients' scores increased with SPEAK use, it is hypothesized that they accommodated to the shift in frequency of incoming sound to a higher pitch percept with the implant than would normally be perceived acoustically.
引用
收藏
页码:332 / 350
页数:19
相关论文
共 34 条
[1]  
[Anonymous], 1966, SAMTR6655 USAF SCH A
[2]  
Blamey P, 1996, Audiol Neurootol, V1, P293
[3]  
Bredberg G., 1968, Acta Otolaryngol, V236, P1
[4]  
Buus S, 1986, AUDITORY FREQUENCY S, P341
[5]  
Cohen L T, 1996, Audiol Neurootol, V1, P278
[6]  
Cohen LT, 1996, AM J OTOL, V17, P859
[7]   SPEECH-PERCEPTION USING A 2-FORMANT 22-ELECTRODE COCHLEAR PROSTHESIS IN QUIET AND IN NOISE [J].
DOWELL, RC ;
SELIGMAN, PM ;
BLAMEY, PJ ;
CLARK, GM .
ACTA OTO-LARYNGOLOGICA, 1987, 104 (5-6) :439-446
[8]   Effects of electrode configuration and frequency allocation on vowel recognition with the nucleus-22 cochlear implant [J].
Fu, QJ ;
Shannon, RV .
EAR AND HEARING, 1999, 20 (04) :332-344
[9]   Effects of electrode location and spacing on phoneme recognition with the nucleus-22 cochlear implant [J].
Fu, QJ ;
Shannon, RV .
EAR AND HEARING, 1999, 20 (04) :321-331
[10]   Recognition of spectrally degraded and frequency-shifted vowels in acoustic and electric hearing [J].
Fu, QJ ;
Shannon, RV .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (03) :1889-1900