Dynamic susceptibility contrast-enhanced echo-planar imaging of cerebral gliomas -: Effect of contrast medium extravasation

被引:21
作者
Essig, M
Wenz, F
Scholdei, R
Brüning, R
Berchtenbreiter, C
Meurer, M
Knopp, MV
机构
[1] Deutsch Krebsforschungszentrum, Dept Radiol, DE-69120 Heidelberg, Germany
[2] Klinikum Grosshadern, Dept Radiol, Munich, Germany
[3] Nycomed Amersham Imaging, Ismaning, Germany
关键词
brain tumors; blood-brain barrier; perfusion MR imaging;
D O I
10.1034/j.1600-0455.2002.430402.x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the influence of the degree of contrast medium extravasation on different DSC EPI MR sequences for perfusion MR imaging. Material and Methods: 60 patients with cerebral gliomas were examined by either an FID EPI or an SE EPI DSC MR sequence. The acquired images were evaluated on a qualitative and quantitative basis. For qualitative assessment, the homogeneity of the signal time curve, image artifacts, the degree of signal drop and the degree of enhancement were evaluated. The quantitative assessment included the percentage of signal drop and the contrast-to-noise ratio of the different EPI sequences was analyzed. Results: FID EPI presented a more homogeneous signal time curve and a more pronounced susceptibility effect than the SE EPI sequence. Due to the lesser susceptibility effect, the SE EPI sequence was not as sensitive to contrast media extravasation. The signal returned to baseline in all patients. In patients with strongly enhancing lesions, the FID EPI sequence suffered from considerable T1 effects, causing problems in the quantification of perfusion data. Conclusion: FID EPI sequences were preferred for perfusion MR imaging in patients without strong enhancing lesions, e.g. in ischemia or tumors with intact blood-brain barrier. In patients with suspected strong enhancing lesions, an SE EPI sequence should be used.
引用
收藏
页码:354 / 359
页数:6
相关论文
共 22 条
[1]   Multisection cerebral blood flow MR imaging with continuous arterial spin labeling [J].
Alsop, DC ;
Detre, JA .
RADIOLOGY, 1998, 208 (02) :410-416
[2]   Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: Influence of time resolution, maximal signal drop and signal-to-noise [J].
Benner, T ;
Heiland, S ;
Erb, G ;
Forsting, M ;
Sartor, K .
MAGNETIC RESONANCE IMAGING, 1997, 15 (03) :307-317
[3]  
Bruening R, 2000, AM J NEURORADIOL, V21, P1603
[4]  
BURGER PC, 1985, CANCER, V56, P1106, DOI 10.1002/1097-0142(19850901)56:5<1106::AID-CNCR2820560525>3.0.CO
[5]  
2-2
[6]   CEREBRAL BLOOD-FLOW - ASSESSMENT WITH DYNAMIC CONTRAST-ENHANCED T2-STAR-WEIGHTED MR IMAGING AT 1.5-T [J].
EDELMAN, RR ;
MATTLE, HP ;
ATKINSON, DJ ;
HILL, T ;
FINN, JP ;
MAYMAN, C ;
RONTHAL, M ;
HOOGEWOUD, HM ;
KLEEFIELD, J .
RADIOLOGY, 1990, 176 (01) :211-220
[7]   EFFECTS OF CEREBRAL ANGIOMAS ON PERIFOCAL AND REMOTE TISSUE - A MULTIVARIATE POSITRON EMISSION TOMOGRAPHY STUDY [J].
FINK, GR .
STROKE, 1992, 23 (08) :1099-1105
[8]   Brain MR perfusion imaging in humans - Advantages of high-molarity gadolinium chelates [J].
Griffiths, PD ;
Wilkinson, ID ;
Wels, T ;
Hoggard, N .
ACTA RADIOLOGICA, 2001, 42 (06) :555-559
[9]   Simultaneous assessment of cerebral hemodynamics and contrast agent uptake in lesions with disrupted blood-brain-barrier [J].
Heiland, S ;
Benner, T ;
Debus, J ;
Rempp, K ;
Reith, W ;
Sartor, K .
MAGNETIC RESONANCE IMAGING, 1999, 17 (01) :21-27
[10]   QUANTIFICATION OF RELATIVE CEREBRAL BLOOD-FLOW CHANGE BY FLOW-SENSITIVE ALTERNATING INVERSION-RECOVERY (FAIR) TECHNIQUE - APPLICATION TO FUNCTIONAL MAPPING [J].
KIM, SG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :293-301