Electrochemical detection of free chlorine using anodic current

被引:21
作者
Kodera, F [1 ]
Kishioka, S [1 ]
Umeda, M [1 ]
Yamada, A [1 ]
机构
[1] Nagaoka Univ Technol, Fac Engn, Dept Chem, Nagaoka, Niigata 9402188, Japan
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS | 2004年 / 43卷 / 7A期
关键词
free chlorine; anodic current; electroanalytical method; linear sweep voltammetry; platinum disk electrode;
D O I
10.1143/JJAP.43.L913
中图分类号
O59 [应用物理学];
学科分类号
摘要
We have developed a new analysis method for high free-chlorine concentration using anodic current. The measurement was carried out using linear sweep voltammetry with a platinum disk electrode. An oxidation wave that was concentration dependent at about 1100 mV vs Ag/AgCl was observed, and a good linear relationship in the concentration range of 0.1-12.0 mmol(.)dm(-3) (Cl) was obtained between the oxidation peak current and concentration. This method seemed to be very useful for the analysis of high free-chlorine concentration.
引用
收藏
页码:L913 / L914
页数:2
相关论文
共 12 条
[1]  
APHA (American Public Health Association), 1992, Standard Methods for the Examination of Water and Wastewater, V18th, P4
[2]   ELECTROCHEMICAL OXIDATION OF HYPOCHLORITE AT PLATINUM ANODES [J].
CZARNETZKI, L ;
JANSSEN, LJJ .
ELECTROCHIMICA ACTA, 1988, 33 (04) :561-566
[3]  
DJORDJEVIC AB, 1973, ELECTROCHIM ACTA, V18, P456
[4]  
F Allen J Bard L.R., 2001, Electrochemical Methods: Fundamentals and Applications
[5]   BEHAVIOUR OF HYPOCHLORITE AND OF N-CHLOROAMINES AT THE DROPPING MERCURY ELECTRODE [J].
HELLER, K ;
JENKINS, EN .
NATURE, 1946, 158 (4020) :706-706
[6]   Development of detector for the flow analysis of residual chlorine using a platinum oxide sheet electrode [J].
Nagashima, K ;
Furui, H ;
Ejiri, M ;
Nakano, N .
BUNSEKI KAGAKU, 2002, 51 (12) :1175-1178
[7]   Simple miniaturized amperometric flow cell for monitoring residual chlorine in tap water [J].
Okumura, A ;
Hirabayashi, A ;
Sasaki, Y ;
Miyake, R .
ANALYTICAL SCIENCES, 2001, 17 (09) :1113-1115
[8]   ANODIC-OXIDATION MECHANISM OF HYPOCHLORITE ION ON PLATINUM-ELECTRODE IN ALKALINE-SOLUTION [J].
TASAKA, A ;
TOJO, T .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1985, 132 (08) :1855-1859
[9]   FLOW-INJECTION AMPEROMETRIC DETERMINATION OF CHLORINE AT A GOLD ELECTRODE [J].
TSAOUSIS, AN ;
HUBER, CO .
ANALYTICA CHIMICA ACTA, 1985, 178 (02) :319-323
[10]   RAPID COULOMETRY WITH A POROUS CARBON FELT ELECTRODE USING IODIDE OR FERROCYANIDE ION MEDIATORS [J].
UCHIYAMA, S ;
SUZUKI, S ;
HAMAMOTO, O .
ELECTROANALYSIS, 1989, 1 (04) :323-326