Renewable-based low-temperature district heating for existing buildings in various stages of refurbishment

被引:118
作者
Brand, Marek [1 ]
Svendsen, Svend [2 ]
机构
[1] Tech Univ Denmark, Dept Civil Engn, DK-2800 Lyngby, Denmark
[2] Tech Univ Denmark, DK-2800 Lyngby, Denmark
关键词
Low-temperature district heating; Existing buildings; Supply temperature curve; Domestic hot water; IDA-ICE; Renewable heat sources;
D O I
10.1016/j.energy.2013.09.027
中图分类号
O414.1 [热力学];
学科分类号
摘要
Denmark is aiming for a fossil-free heating sector for buildings by 2035. Judging by the national heating plan, this will be achieved mainly by a further spread of DH (district heating) based on the renewable heat sources. To make the most cost-effective use of these sources, the DH supply temperature should be as low as possible. We used IDA-ICE software to simulate a typical Danish single-family house from the 1970s connected to DH at three different stages of envelope and space heating system refurbishment. We wanted to investigate how low the DH supply temperature can be without reducing the current high level of thermal comfort for occupants or the good efficiency of the DH network. Our results show that, for a typical single-family house from the 1970s, even a small refurbishment measure such as replacing the windows allows the reduction of the maximum DH supply temperature from 78 to 67 degrees C and, for 98% of the year, to below 60 degrees C. However for the temperatures below 60 degrees C a low-temperature DH substation is required for DHW (domestic hot water) heating. This research shows that renewable sources of heat can be integrated into the DH system without problems and contribute to the fossil-free heating sector already today. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:311 / 319
页数:9
相关论文
共 19 条
[1]  
Aalborg University and Ramboll, 2008, HEAT PLAN DENM
[2]  
[Anonymous], 2011, FINAL REPORT EUDP 20
[3]  
[Anonymous], 2011, TEKN LEG SANKT TAPPV
[4]  
[Anonymous], 2011, 418 DS
[5]  
[Anonymous], 11 INT S DISTR HEAT
[6]  
[Anonymous], 2009, FINAL REPORT EFP 200
[7]  
Becher P., 1972, VARME VENTILATION 2
[8]  
Bolius - boligejernes videncenter, EN PARC 1973
[9]  
Brand M, 2012, P PASSIVHUS NORD OCT
[10]   Numerical modelling and experimental measurements for a low-temperature district heating substation for instantaneous preparation of DHW with respect to service pipes [J].
Brand, Marek ;
Thorsen, Jan Eric ;
Svendsen, Svend .
ENERGY, 2012, 41 (01) :392-400