Comparison and verification of bacterial water quality indicator measurement methods using ambient coastal water samples

被引:23
作者
Griffith, John F.
Aumand, Larissa A.
Lee, Ioannice M.
McGee, Charles D.
Othman, Laila L.
Ritter, Kerry J.
Walker, Kathy O.
Weisberg, Stephen B.
机构
[1] So Calif Coastal Water Res Project, Westminster, CA 92683 USA
[2] MEC, Analyt Syst Inc, Carlsbad, CA USA
[3] City Los Angeles Dept Sanitat, Los Angeles, CA USA
[4] Orange Cty Sanitat Dist, Fountian Valley, CA USA
[5] City San Diego, Metropolitan Waste Water Dept, San Diego, CA USA
[6] Los Angeles Cty Sanit Dist, Whittier, CA USA
关键词
fecal indicator bacteria; laboratory intercalibration; method comparison; water quality;
D O I
10.1007/s10661-006-7571-z
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
More than 30 laboratories routinely monitor water along southern California's beaches for bacterial indicators of fecal contamination. Data from these efforts frequently are combined and compared even though three different methods (membrane filtration (MF), multiple tube fermentation (MTF), and chromogenic substrate (CS) methods) are used. To assess data comparability and quantify variability within method and across laboratories, 26 laboratories participated in an intercalibration exercise. Each laboratory processed three replicates from eight ambient water samples employing the method or methods they routinely use for water quality monitoring. Verification analyses also were conducted on a subset of wells from the CS analysis to confirm or exclude the presence of the target organism. Enterococci results were generally comparable across methods. Confirmation revealed a 9% false positive rate and a 4% false negative rate in the CS method for enterococci, though these errors were small in the context of within- and among-laboratory variability. Fecal coliforms also were comparable across all methods, though CS underestimated the other methods by about 10%, probably because it measures only E. coli, rather than the larger fecal coliform group measured by MF and MTF. CS overestimated total coliforms relative to the other methods by several fold and was found to have a 40% false positive rate in verification. Across-laboratory variability was small relative to within- and among-method variability, but only after data entry errors were corrected. One fifth of the laboratories committed data entry errors that were much larger than any method-related errors. These errors are particularly significant because these data were submitted in a test situation where laboratories were aware they would be under increased scrutiny. Under normal circumstances, it is unlikely that these errors would have been detected and managers would have been obliged to issue beach water quality warnings.
引用
收藏
页码:335 / 344
页数:10
相关论文
共 20 条