Measurements of gastric emptying during continuous nasogastric infusion of liquid feed: Electric impedance tomography versus gamma scintigraphy

被引:57
作者
Soulsby, Clare T.
Khela, Mandeep
Yazaki, Etsuro
Evans, David F.
Hennessy, Enid
Powell-Tuck, Jeremy
机构
[1] Barts & London Med Sch, Inst Cell & Mol Sci, Ctr Adult & Paediat Gastroenterol, London, England
[2] Barts & London Med Sch, Stat Wolfson Inst Prevent Med, London, England
关键词
enteral feed; continuous nasogastric infusion; electric impedance tomography (EIT); gamma scintigraphy; gastric residual volume (GRV);
D O I
10.1016/j.clnu.2005.11.015
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 [营养与食品卫生学];
摘要
Background & aims: Continuous nasogastric infusion is commonly used to deliver enteral feed but current methods used to assess tolerance based on aspiration and measurement of gastric residual volume have been criticised. Electric impedance tomography (EIT) measures gastric emptying by monitoring changes in epigastric impedance when a meat progressively empties from the stomach. Aims: (1) to establish whether EIT was a valid method for measuring gastric emptying during continuous nasogastric infusion by comparing it with gamma scintigraphy (GS) and (2) to provide data on gastric emptying patterns during continuous nasogastric infusion. Methods: Gastric emptying of 400 ml of enteral feed given over 200 min was measured simultaneously using EIT and GS in 10 healthy volunteers (five mate and five female). Results: Gastric emptying curves were obtained in 10 subjects by EIT but only eight by GS. Visual examination of the curves showed reasonable agreement. Patterns of emptying and filling during continuous nasogastric infusion were variable between individuals; the prevailing pattern was a trend towards a steady-state volume of approximately 50-125 ml. Conclusions: While EIT does not provide an accurate estimate of gastric volume during continuous infusion, it does show patterns of gastric emptying over time. With further development this could make it a useful toot for monitoring gastric emptying in patients at risk of gastroparesis. (C) 2006 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
引用
收藏
页码:671 / 680
页数:10
相关论文
共 14 条
[1]
AKKERMANS LMA, 1994, DIG DIS SCI S, V39, P95
[2]
APPLIED POTENTIAL TOMOGRAPHY - A NEW NONINVASIVE TECHNIQUE FOR MEASURING GASTRIC-EMPTYING [J].
AVILL, R ;
MANGNALL, YF ;
BIRD, NC ;
BROWN, BH ;
BARBER, DC ;
SEAGAR, AD ;
JOHNSON, AG ;
READ, NW .
GASTROENTEROLOGY, 1987, 92 (04) :1019-1026
[3]
Burd R, 2001, NUTR CLIN PRACT, V16, P349
[4]
Labeled acetate to assess intestinal absorption in critically ill patients [J].
Chioléro, RL ;
Revelly, JP ;
Berger, MM ;
Cayeux, MC ;
Schneiter, P ;
Tappy, L .
CRITICAL CARE MEDICINE, 2003, 31 (03) :853-857
[5]
GABRIEL C, COMPLICATION DIELECT
[6]
Stopping enteral feeding for arbitrary gastric residual volume may not be physiologically sound: Results of a computer simulation model [J].
Lin, HC ;
VanCitters, GW .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1997, 21 (05) :286-289
[7]
APPLIED POTENTIAL TOMOGRAPHY - NONINVASIVE METHOD FOR MEASURING GASTRIC-EMPTYING OF A SOLID TEST MEAL [J].
MANGNALL, YF ;
KERRIGAN, DD ;
JOHNSON, AG ;
READ, NW .
DIGESTIVE DISEASES AND SCIENCES, 1991, 36 (12) :1680-1684
[8]
USE OF RESIDUAL VOLUME AS A MARKER FOR ENTERAL FEEDING INTOLERANCE - PROSPECTIVE BLINDED COMPARISON WITH PHYSICAL-EXAMINATION AND RADIOGRAPHIC FINDINGS [J].
MCCLAVE, SA ;
SNIDER, HL ;
LOWEN, CC ;
MCLAUGHLIN, AJ ;
GREENE, LM ;
MCCOMBS, RJ ;
RODGERS, L ;
WRIGHT, RA ;
ROY, TM ;
SCHUMER, MP ;
PFEIFER, MA .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1992, 16 (02) :99-105
[9]
McClave Stephen A., 2002, Journal of Parenteral and Enteral Nutrition, V26, pS43, DOI 10.1177/014860710202600607
[10]
APPLIED POTENTIAL TOMOGRAPHY IN THE MEASUREMENT OF GASTRIC-EMPTYING IN INFANTS [J].
NOUR, S ;
MANGNALL, YF ;
DICKSON, JAS ;
JOHNSON, AG ;
PEARSE, RG .
JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1995, 20 (01) :65-72