Detection and manipulation of biomolecules by magnetic carriers

被引:72
作者
Brzeska, M
Panhorst, M
Kamp, PB
Schotter, J
Reiss, G
Pühler, A
Becker, A
Brückl, H
机构
[1] Univ Bielefeld, Dept Phys, D-33615 Bielefeld, Germany
[2] Univ Bielefeld, Dept Genet, D-33615 Bielefeld, Germany
关键词
molecular recognition; biochip; marker; sensor; magnetoresistive; bonding force;
D O I
10.1016/j.jbiotec.2004.04.018
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The detection and manipulation of single molecules on a common platform would be of great interest for basic research of biological or chemical systems. A promising approach is the application of magnetic carriers. The principles are demonstrated in this contribution. It is shown that paramagnetic beads can be detected by highly sensitive magnetoresistive sensors yielding a purely electronic signal. Different configurations are discussed. The capability of the sensors to detect even single markers is demonstrated by a model experiment. In addition, the paramagnetic beads can be used as carriers for biomolecules. They can be manipulated on-chip via currents running through specially designed line patterns. Thus, magnetic markers in combination with magnetoresistive sensors are a promising choice for future integrated lab-on-a-chip systems. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 33
页数:9
相关论文
共 15 条
[1]   GIANT MAGNETORESISTANCE OF (001)FE/(001) CR MAGNETIC SUPERLATTICES [J].
BAIBICH, MN ;
BROTO, JM ;
FERT, A ;
VANDAU, FN ;
PETROFF, F ;
EITENNE, P ;
CREUZET, G ;
FRIEDERICH, A ;
CHAZELAS, J .
PHYSICAL REVIEW LETTERS, 1988, 61 (21) :2472-2475
[2]   A biosensor based on magnetoresistance technology [J].
Baselt, DR ;
Lee, GU ;
Natesan, M ;
Metzger, SW ;
Sheehan, PE ;
Colton, RJ .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) :731-739
[3]  
Brückl H, 2003, ADV SOLID STATE PHYS, V43, P397
[4]   Single magnetic microsphere placement and detection on-chip using current line designs with integrated spin valve sensors: Biotechnological applications [J].
Graham, DL ;
Ferreira, H ;
Bernardo, J ;
Freitas, PP ;
Cabral, JMS .
JOURNAL OF APPLIED PHYSICS, 2002, 91 (10) :7786-7788
[5]   LAYERED MAGNETIC-STRUCTURES - EVIDENCE FOR ANTIFERROMAGNETIC COUPLING OF FE LAYERS ACROSS CR INTERLAYERS [J].
GRUNBERG, P ;
SCHREIBER, R ;
PANG, Y ;
BRODSKY, MB ;
SOWERS, H .
PHYSICAL REVIEW LETTERS, 1986, 57 (19) :2442-2445
[6]  
GRUTTER P, 1992, SCANNING TUNNELING M, V2, P152
[7]   On-chip manipulation and magnetization assessment of magnetic bead ensembles by integrated spin-valve sensors [J].
Lagae, L ;
Wirix-Speetjens, R ;
Das, J ;
Graham, D ;
Ferreira, H ;
Freitas, PPF ;
Borghs, G ;
De Boeck, J .
JOURNAL OF APPLIED PHYSICS, 2002, 91 (10) :7445-7447
[8]   Microelectromagnets for the control of magnetic nanoparticles [J].
Lee, CS ;
Lee, H ;
Westervelt, RM .
APPLIED PHYSICS LETTERS, 2001, 79 (20) :3308-3310
[9]   LARGE MAGNETORESISTANCE AT ROOM-TEMPERATURE IN FERROMAGNETIC THIN-FILM TUNNEL-JUNCTIONS [J].
MOODERA, JS ;
KINDER, LR ;
WONG, TM ;
MESERVEY, R .
PHYSICAL REVIEW LETTERS, 1995, 74 (16) :3273-3276
[10]  
*OOMMF, 2003, OOMMF SOFTW