Laser activated voltammetry: application to the determination of phenol in aqueous solution at a glassy carbon electrode

被引:12
作者
Fulian, Q [1 ]
Compton, RG [1 ]
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
关键词
D O I
10.1039/a908826a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Clean electrode surfaces can be achieved during the electrolysis of otherwise passivating species in aqueous and other solutions by means of surface ablation using a 10 Hz pulsed Nd:YAG 532 nm laser. This ability to remove passivating electrolytically generated layers on a glassy carbon electrode in a channel flow cell was shown by an investigation of the stripping peaks formed from the electrogeneration of the neutral forms of methyl viologen and heptyl viologen during reduction in aqueous solution of the corresponding di-cations. Next, laser ablation voltammetry was conducted for the oxidation of phenol in aqueous solution. Steady state voltammograms were obtained with well defined mass transport limited currents contrasting with the current peaks seen under dark scans where the formation of a polymerised layer on the electrode surface ultimately leads to electrode passivation under flow conditions. Square wave voltammetry was then used to detect phenol under no-flow conditions using a laser intensity of 0.1 W cm(-2). A linear dependence of the peak current on the concentration was found with a detection limit of phenol of 2 mu M.
引用
收藏
页码:531 / 534
页数:4
相关论文
共 27 条
[1]  
Adams R.N., 1969, Electrochemistry at Solid Electrodes
[2]   Laser-activated voltammetry.: Mechanism of aqueous iodide oxidation at platinum electrodes:: Theory and experiment [J].
Akkermans, RP ;
Qiu, FL ;
Roberts, SL ;
Suárez, MF ;
Compton, RG .
JOURNAL OF PHYSICAL CHEMISTRY B, 1999, 103 (39) :8319-8327
[3]  
AKKERMANS RT, 1999, ELECTROANAL, V16, P11
[4]   TRACE DETERMINATION OF PHENOLIC-COMPOUNDS IN WATER BY REVERSED PHASE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION USING A CARBON-POLYETHYLENE TUBULAR ANODE [J].
ARMENTROUT, DN ;
MCLEAN, JD ;
LONG, MW .
ANALYTICAL CHEMISTRY, 1979, 51 (07) :1039-1045
[5]   CAPILLARY DIFFUSION MEASUREMENTS USING FLUORESCENCE ANALYSIS - D-VALUES OF SOME ELECTROCHEMICALLY IMPORTANT SYSTEMS [J].
BACON, J ;
ADAMS, RN .
ANALYTICAL CHEMISTRY, 1970, 42 (04) :524-&
[6]   ELECTROCHEMISTRY OF THE VIOLOGENS [J].
BIRD, CL ;
KUHN, AT .
CHEMICAL SOCIETY REVIEWS, 1981, 10 (01) :49-82
[7]  
Burttschell R. H., 1959, J AM WATER WORKS ASS, V51, P205, DOI 10.1002/j.1551-8833.1959.tb15722.x
[8]  
CANETE F, 1988, ANAL CHIM ACTA, V214, P375, DOI 10.1016/S0003-2670(00)80458-4
[9]  
COMPTON RG, 1995, PROG REACT KINET MEC, V20, P245
[10]   INVESTIGATION OF THE NATURE OF ELECTRODEPOSITED NEUTRAL VIOLOGENS FORMED BY REDUCTION OF THE DICATIONS [J].
ENGELMAN, EE ;
EVANS, DH .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 349 (1-2) :141-158