Nafion-methylene blue functional membrane and its application in chemical and biosensing

被引:24
作者
Hong, Jun [1 ]
Ghourchian, Hedayatollah [1 ]
Rezaei-Zarchi, Saeed [1 ]
Moosavi-Movahedi, Ali Akbar [1 ]
Ahmadian, Shahin [1 ]
Saboury, Ali Akbar [1 ]
机构
[1] Univ Tehran, Inst Biochem & Biophys, Tehran 1981813563, Iran
基金
美国国家科学基金会;
关键词
methylene blue; Nafion; functional membrane; biosensor; HRP; hydrogen peroxide;
D O I
10.1080/00032710601017664
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A functional membrane composed of nanoparticles of methylene blue and Nafion perfluorosulfonated ion-exchange resin ( Nafion (R)) was constructed and characterized by the methods of scanning electron microscope, transmission electron microscope, UV-vis, and Fourier transform infrared. The membrane at glassy carbon electrode was directly applicable for determining H2O2 concentration. Furthermore, horseradish peroxidase was immobilized on the membrane, which showed a quasi-reversible electrochemical behavior with a formal potential of 2296 mV. The resulting biosensor exhibited a good stability and higher sensitivity to H2O2 relative to the membrane without horseradish perioxidase. The linear range of this biosensor for H2O2 determination was from 2 x 10(-5) to 7 x 10(-3) M, with detection limit of 7 x 10(-6) M.
引用
收藏
页码:483 / 496
页数:14
相关论文
共 28 条
[1]   Silicon oxide Nafion composite membranes for proton-exchange membrane fuel cell operation at 80-140° C [J].
Adjemian, KT ;
Lee, SJ ;
Srinivasan, S ;
Benziger, J ;
Bocarsly, AB .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2002, 149 (03) :A256-A261
[2]   ELECTROCHEMISTRY IN HYDROPHOBIC NAFION GELS .1. ELECTROCHEMICAL-BEHAVIOR OF ELECTRODES MODIFIED BY HYDROPHOBIC NAFION GELS LOADED WITH FERROCENES [J].
ANDRIEUX, CP ;
AUDEBERT, P ;
DIVISIABLOHORN, B ;
ALDEBERT, P ;
MICHALAK, F .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 296 (01) :117-128
[3]   THEORY OF IRREVERSIBLE CYCLIC VOLTAMMOGRAMS AT MICROCYLINDER ELECTRODES [J].
AOKI, K ;
KANEKO, H .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 247 (1-2) :17-27
[4]   Electrochemical study of methylene blue incorporated into mordenite type zeolite and its application for amperometric determination of ascorbic acid in real samples [J].
Arvand, M ;
Sohrabnezhad, S ;
Mousavi, MF ;
Shamsipur, M ;
Zanjanchi, MA .
ANALYTICA CHIMICA ACTA, 2003, 491 (02) :193-201
[5]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[6]   Mediated biosensors [J].
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :441-456
[7]   METHYLENE-BLUE PERFLUOROSULFONATED IONOMER MODIFIED MICROCYLINDER CARBON-FIBER ELECTRODE AND ITS APPLICATION FOR THE DETERMINATION OF HEMOGLOBIN [J].
CHEN, HY ;
JU, HX ;
XUN, YG .
ANALYTICAL CHEMISTRY, 1994, 66 (24) :4538-4542
[8]   Methylene blue immobilized on cellulose surfaces modified with titanium dioxide and titanium phosphate: factorial design optimization of redox properties [J].
Dias, SLP ;
Fujiwara, ST ;
Gushikem, Y ;
Bruns, RE .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 531 (02) :141-146
[9]   MEDIATED ELECTROCHEMICAL REDUCTION OF CYTOCHROME-C AND TYROSINASE AT PERFLUOROSULFONATED IONOMER COATED ELECTRODES [J].
FURBEE, JW ;
THOMAS, CR ;
KELLY, RS ;
MALACHOWSKI, MR .
ANALYTICAL CHEMISTRY, 1993, 65 (13) :1654-1657
[10]   AMPEROMETRIC BIOSENSORS BASED ON AN APPARENT DIRECT ELECTRON-TRANSFER BETWEEN ELECTRODES AND IMMOBILIZED PEROXIDASES - PLENARY LECTURE [J].
GORTON, L ;
JONSSONPETTERSSON, G ;
CSOREGI, E ;
JOHANSSON, K ;
DOMINGUEZ, E ;
MARKOVARGA, G .
ANALYST, 1992, 117 (08) :1235-1241