Error in Central Venous Pressure Measurement

被引:50
作者
Figg, Katie K. [1 ]
Nemergut, Edward C. [2 ]
机构
[1] Univ Virginia, Hlth Sci Ctr, Dept Anesthesiol, Charlottesville, VA 22908 USA
[2] Univ Virginia, Hlth Sci Ctr, Dept Neurosurg, Charlottesville, VA 22908 USA
关键词
ASPIRATION; POSITION;
D O I
10.1213/ane.0b013e318196482c
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: The variability introduced by inconsistent placement of pressure transducers for invasive monitoring may result in significant measurement error. Our goals in this study were to quantify the degree of variation among health care providers and to identify a simple tool for reducing this error. METHODS: A sample of 50 perioperative health care providers was recruited and asked to place a transducer at the appropriate level for central venous pressure (CVP) monitoring on two separate occasions: first without any additional standardization tools and second with a laser level to guide transducer placement. The variability among providers was calculated, and the results between sessions compared. RESULTS: There was significant variation in transducer placement during both sessions, in some instances, of greater magnitude than a normal CVP value. The laser level did not significantly reduce this variation. CONCLUSION: There is significant variation in transducer placement among health care providers. This variation is not reduced by a laser level and must be considered when interpreting CVP data. Hospital- or institution-wide standardization of a zero-level should be considered.
引用
收藏
页码:1209 / 1211
页数:3
相关论文
共 6 条
  • [1] Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine
    Atkinson, G
    Nevill, AM
    [J]. SPORTS MEDICINE, 1998, 26 (04) : 217 - 238
  • [2] Central venous pressure monitoring
    Magder, Sheldon
    [J]. CURRENT OPINION IN CRITICAL CARE, 2006, 12 (03) : 219 - 227
  • [3] Tracheobronchial aspiration of gastric contents in critically ill tube-fed patients: Frequency, outcomes, and risk factors
    Metheny, NA
    Clouse, RE
    Chang, YH
    Stewart, BJ
    Oliver, DA
    Kollef, MH
    [J]. CRITICAL CARE MEDICINE, 2006, 34 (04) : 1007 - 1015
  • [4] SEMIRECUMBENT POSITION PROTECTS FROM PULMONARY ASPIRATION BUT NOT COMPLETELY FROM GASTROESOPHAGEAL REFLUX IN MECHANICALLY VENTILATED PATIENTS
    OROZCOLEVI, M
    TORRES, A
    FERRER, M
    PIERA, C
    ELEBIARY, M
    DELABELLACASA, JP
    RODRIGUEZROISIN, R
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 152 (04) : 1387 - 1390
  • [5] Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge
    Osman, David
    Ridel, Christophe
    Ray, Patrick
    Monnet, Xavier
    Anguel, Nadia
    Richard, Christian
    Teboul, Jean-Louis
    [J]. CRITICAL CARE MEDICINE, 2007, 35 (01) : 64 - 68
  • [6] Uppermost blood levels of the right and left atria in the supine position - Implication for measuring central venous pressure and pulmonary artery wedge pressure
    Seo, Jeong-Hwa
    Jung, Chul-Woo
    Bahk, Jae-Hyon
    [J]. ANESTHESIOLOGY, 2007, 107 (02) : 260 - 263