Handgrip contribution to lactate production and leg power during high-intensity exercise

被引:33
作者
Baker, J [1 ]
Brown, E [1 ]
Hill, G [1 ]
Phillips, G [1 ]
Williams, R [1 ]
Davies, B [1 ]
机构
[1] Univ Glamorgan, Field Hlth & Exercise Sci, Sch Appl Sci, Pontypridd CF37 1DL, M Glam, Wales
关键词
wingate test; cycle ergometry;
D O I
10.1097/00005768-200206000-00021
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
BAKER, J., E. BROWN, G. HILL, G. PHILLIPS, R. WILLIAMS, and B. DAVIES. Handgrip contribution to lactate production and leg power during high-intensity exercise. Med. Sci. Sports Exerc., Vol. 34, No. 6, pp. 1037-1040, 2002. Purpose: The purpose of this study was to examine the upper-body contribution via handgrip to power profiles and blood lactate concentrations during high-intensity cycle ergometry. Methods: Nine trained male subjects each completed a 20-s high-intensity cycle ergometer test twice, in a random manner, using two protocols, with a handgrip (WG), and without handgrip (WOHG). Capillary (earlobe) blood samples were obtained pre- and post-exercise. Blood samples were corrected for plasma volume changes and analyzed to determine blood lactate concentrations. Results: In the WG protocol, mean ( SEM) blood lactate concentrations sampled over the three conditions were 0.98 +/- 0.33 mmol.L-1, 5.68 +/- 0.46 mmol.L-1, and 9.14 +/- 0.38 mmol.L-1, respectively. During the WOHG protocol, blood lactate values recorded were 0.99 +/- 0.26 mmol.L-1, 5.58 +/- 0.58 mmol.L-1, and 7.62 +/- 0.65 mmol.L-1, respectively. Differences were found (P < 0.05) from rest to 4 min after exercise for both groups. Differences in concentrations were also observed between groups at the 4-min postexercise blood-sampling stage. Peak power output values recorded using the WG protocol were also greater (1461 +/- 94 W vs 1136 +/- 88 W; P < 0.05). No differences were recorded for mean power output (MPO), fatigue index (FI), or work done (WD). Conclusion: Results indicate significant differences in power output and blood lactate concentrations between protocols. These findings suggest that the performance of traditional style leg-cycle ergometry requires a muscular contribution from the whole body. As such, researchers should consider this, both in terms of the allocation of ergometer loads, and in the analysis of blood-borne metabolites.
引用
收藏
页码:1037 / 1040
页数:4
相关论文
共 16 条
[2]  
AYLON A, 1974, INT SERIES SPORTS SC, V4, P572
[3]   Power output of legs during high intensity cycle ergometry: Influence of hand grip [J].
Baker, J ;
Gal, J ;
Davies, B ;
Bailey, D ;
Morgan, R .
JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2001, 4 (01) :10-18
[4]   THE WINGATE ANAEROBIC TEST - AN UPDATE ON METHODOLOGY, RELIABILITY AND VALIDITY [J].
BAROR, O .
SPORTS MEDICINE, 1987, 4 (06) :381-394
[5]  
Coleman S., 1996, CORRECTED WINGATE AN, P4
[6]   CALCULATION OF PERCENTAGE CHANGES IN VOLUMES OF BLOOD, PLASMA, AND RED-CELLS IN DEHYDRATION [J].
DILL, DB ;
COSTILL, DL .
JOURNAL OF APPLIED PHYSIOLOGY, 1974, 37 (02) :247-248
[7]   LOAD OPTIMIZATION FOR THE WINGATE ANAEROBIC TEST [J].
DOTAN, R ;
BAROR, O .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1983, 51 (03) :409-417
[8]  
INBAR O, 1996, WINGATE ANAEROBIC TE, P32
[9]   Comparison of treadmill and cycle ergometer measurements of force-velocity relationships and power output [J].
Jaskólska, A ;
Goossens, P ;
Veenstra, B ;
Jaskólski, A ;
Skinner, JS .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1999, 20 (03) :192-197
[10]  
Libonati J R, 1998, Cardiologia, V43, P1355