Measurement of liver blood volume using a macromolecular MRI contrast agent at equilibrium

被引:10
作者
Blustajn, J [1 ]
Cuenod, CA [1 ]
Clement, O [1 ]
Siauve, N [1 ]
VuilleminBodaghi, V [1 ]
Frija, G [1 ]
机构
[1] FAC NECKER ENFANTS MALAD,LAB RECH IMAGERIE,F-75015 PARIS,FRANCE
关键词
magnetic resonance imaging; liver; blood volume; contrast agent;
D O I
10.1016/S0730-725X(96)00379-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Liver regional blood volume (LRBV) is altered by several disease states and various drugs. Preliminary studies in the rat, using research MR imaging instruments at 2T and vascular contrast agents, have suggested that MRI may be used to measure LRBV. Our goal was to develop a technique for measuring LRBV using a clinical machine at 1.5 T. This study was performed in the rabbit, using CarboxyMethylDextran Gd-DTPA, a macromolecular contrast agent with a molecular weight of 158 kDa, MRI was performed at 1.5 T, in the plane of the inferior vena cava, with and without how compensation, before contrast injection and in the steady state after injection, Accuracy and stability of LRBV measurement, over 2 h and with various doses (0.01-0.05 mmol/kg), was tested against a standard Evan's Blue dye-indicator technique, LRBV was 28 +/- 2 mL/100 g when measured by MRI with flow compensation, which is in good agreement with the literature and with the 26 +/- 6 mL/100 g, measured by the Evan's Blue dilution technique, Measurements varied less than 7% over time and less than 9% over the range of doses, LRBV was overestimated using a sequence without flow compensation especially when large doses of contrast agent were injected. This noninvasive MRI technique provides a simple method for measuring liver LRBV and offers new prospects for future physiological and pathological studies. (C) 1997 Elsevier Science Inc.
引用
收藏
页码:415 / 421
页数:7
相关论文
共 18 条
[1]
DISTRIBUTION OF EXTRA PLASMA IN THE BLOOD OF SOME TISSUES IN THE DOG AS MEASURED WITH P-32 AND T-1824 [J].
ALLEN, TH ;
REEVE, EB .
AMERICAN JOURNAL OF PHYSIOLOGY, 1953, 175 (02) :218-223
[2]
INFLUENCE OF ALPHA-ADRENERGIC RECEPTOR STIMULATION ON SPLANCHNIC INTRAVASCULAR VOLUME IN CONSCIOUS HUMANS [J].
BELL, L ;
ZARET, BL ;
RUTLEN, DL .
ACTA PHYSIOLOGICA SCANDINAVICA, 1991, 143 (01) :65-69
[3]
CARTER JH, 1961, SURG GYNECOL OBSTET, V113, P133
[4]
EVANS BLUE SPACE IN TISSUES OF THE RAT [J].
CASTER, WO ;
SIMON, AB ;
ARMSTRONG, WD .
AMERICAN JOURNAL OF PHYSIOLOGY, 1955, 183 (02) :317-321
[5]
INDOCYANINE GREEN CLEARANCE IN ACUTE REJECTION AFTER LIVER-TRANSPLANTATION [J].
CLEMENTS, D ;
MCMASTER, P ;
ELIAS, E .
TRANSPLANTATION, 1988, 46 (03) :383-385
[6]
GREENWAY C, 1969, CIRC RES, V25, P227
[7]
BLOOD-VOLUME, THE VENOUS SYSTEM, PRELOAD, AND CARDIAC-OUTPUT [J].
GREENWAY, CV ;
LAUTT, WW .
CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 1986, 64 (04) :383-387
[8]
GROTH CG, 1968, SURGERY, V63, P658
[9]
IMPROVING MR IMAGE QUALITY IN THE PRESENCE OF MOTION BY USING REPHASING GRADIENTS [J].
HAACKE, EM ;
LENZ, GW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (06) :1251-1258
[10]
QUANTIFICATION OF TISSUE-PLASMA VOLUME IN THE RAT BY CONTRAST-ENHANCED MAGNETIC-RESONANCE-IMAGING [J].
KUWATSURU, R ;
SHAMES, DM ;
MUHLER, A ;
MINTOROVITCH, J ;
VEXLER, V ;
MANN, JS ;
COHN, F ;
PRICE, D ;
HUBERTY, J ;
BRASCH, RC .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (01) :76-81