Detection of myocardial injury in patients with unstable angina using a novel nanoparticle cardiac troponin I assay: Observations from the PROTECT-TIMI 30 Trial

被引:74
作者
Wilson, Sean R. [2 ]
Sabatine, Marc S. [2 ]
Braunwald, Eugene [2 ]
Sloan, Sarah [2 ]
Murphy, Sabina A. [2 ]
Morrow, David A. [1 ,2 ]
机构
[1] Brigham & Womens Hosp, Div Cardiovasc, TIMI Study Grp, Boston, MA 02115 USA
[2] Dept Med, Boston, MA USA
关键词
ACUTE CORONARY SYNDROME; ELEVATION; STANDARDIZATION; ISCHEMIA; OUTCOMES; RISK;
D O I
10.1016/j.ahj.2009.06.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background At least 30% of patients with non-ST-elevation acute coronary syndrome present without evidence of myonecrosis using current generation troponin assays. A new generation of research assays for troponin that offer a >10-fold increase in analytical sensitivity has emerged. Methods To perform a pilot study to evaluate the clinical sensitivity of a new ultra-sensitive nanoparticle assay for cardiac troponin I (nano-cTnl), we identified 50 patients with unstable angina (serial negative cTnI) and 50 patients with non-ST-elevation myocardial infarction with an initially negative current generation cTnI result. We measured cTnI using an assay (Nanosphere, Northbrook, IL) that can detect pg/mL concentrations of cTnI (detection-limit 0.0002 mu g/L). Results Measured at 0, 2, and 8 hours with the nano-cTnI assay 44%, 62%, and 82% of patients with unstable angina defined by the current-generation assay had an elevated nano-cTnI result (>= 0.003 mu g/L, 99th percentile decision-limit, coefficient of variation <10%). In patients with definite myocardial injury (current-generation cTnI >= 0.1 mu g/L) but an initially negative cTnI, 72% and 98% had a nano-cTnl 0.003 pg/L at 0 and 2 hours. No patient had a positive current-generation cTnI without an elevated nano-cTnl level. Conclusions In this pilot study using a nanoparticle assay for cTnI, myocardial injury was detectable in a substantial proportion of patients presently classified as having unstable angina, suggesting that ischemia with rest pain without injury is rare. The emergence of a new generation of troponin assays has the potential to lead to new clinical applications based on enhanced analytical performance at very low concentrations of troponin. (Am Heart J 2009; 158:386-91.)
引用
收藏
页码:386 / 391
页数:6
相关论文
共 24 条
[1]   Myocardial infarction redefined -: A consensus Document of the Joint European Society of Cardiology/American College of Cardiology Committee for the Redefinition of Myocardial Infarction [J].
Alpert, JS ;
Antman, E ;
Apple, F ;
Armstrong, PW ;
Bassand, JP ;
de Luna, AB ;
Beller, G ;
Breithardt, G ;
Chaitman, BR ;
Clemmensen, P ;
Falk, E ;
Fishbein, MC ;
Galvani, M ;
Garson, A ;
Grines, C ;
Hamm, C ;
Jaffe, A ;
Katus, H ;
Kjekshus, J ;
Klein, W ;
Klootwijk, P ;
Lenfant, C ;
Levy, D ;
Levy, RI ;
Luepker, R ;
Marcus, F ;
Näslund, U ;
Ohman, M ;
Pahlm, O ;
Poole-Wilson, P ;
Popp, R ;
Alto, P ;
Pyörälä, K ;
Ravkilde, J ;
Rehnquist, N ;
Roberts, W ;
Roberts, R ;
Roelandt, J ;
Rydén, L ;
Sans, S ;
Simoons, ML ;
Thygesen, K ;
Tunstall-Pedoe, H ;
Underwood, R ;
Uretsky, BF ;
Van de Werf, F ;
Voipio-Pulkki, LM ;
Wagner, G ;
Wallentin, L ;
Wijns, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) :959-969
[2]   ACC/AHA 2007 guide lines for the management of patients with unstable Angina/Non-ST-Elevation myocardial infraction - Executive summary [J].
Anderson, Jeffrey L. ;
Adams, Cynthia D. ;
Antman, Elliott M. ;
Bridges, Charles R. ;
Califf, Robert M. ;
Casey, Donald E., Jr. ;
Chavey, William E., II ;
Fesmire, Francis M. ;
Hochman, Judith S. ;
Levin, Thomas N. ;
Lincoff, A. Michael ;
Peterson, Eric D. ;
Theroux, Pierre ;
Wenger, Nanette Kass ;
Wright, R. Scott ;
Smith, Sidney C., Jr. ;
Jacobs, Alice K. ;
Adams, Cynthia D. ;
Riegel, Barbara .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (07) :652-726
[3]   National Academy of Clinical Biochemistry and IFCC Committee for Standardization of Markers of Cardiac Damage Laboratory Medicine Practice Guidelines: Analytical issues for biochemical markers of acute coronary syndromes [J].
Apple, Fred S. ;
Jesse, Robert L. ;
Newby, L. Kristin ;
Wu, Alan H. B. ;
Christenson, Robert H. ;
Cannon, Christopher P. ;
Francis, Gary ;
Morrow, David A. ;
Ravkilde, Jan ;
Storrow, Alan B. ;
Tang, Wilson ;
Jaffe, Allan S. ;
Mair, Johannes ;
Ordonez-Llanos, Jordi ;
Pagani, Franca ;
Panteghini, Mauro ;
Tate, Jillian .
CLINICAL CHEMISTRY, 2007, 53 (04) :547-551
[4]  
APPLE FS, 2008, PRELIMINARY IN PRESS
[5]   Toward standardization of cardiac troponin I measurements part II: Assessing commutability of candidate reference materials and harmonization of cardiac troponin I assays [J].
Christenson, Robert H. ;
Duh, Show Hong ;
Apple, Fred S. ;
Bodor, Geza S. ;
Bunk, David M. ;
Panteghini, Mauro ;
Welch, Michael J. ;
Wu, Alan H. B. ;
Kahn, Stephen E. .
CLINICAL CHEMISTRY, 2006, 52 (09) :1685-1692
[6]   Persistent cardiac troponin I elevation in stabilized patients after an episode of acute coronary syndrome predicts long-term mortality [J].
Eggers, Kai M. ;
Lagerqvist, Bo ;
Venge, Per ;
Wallentin, Lars ;
Lindahl, Bertil .
CIRCULATION, 2007, 116 (17) :1907-1914
[7]   A Randomized trial to evaluate the relative protection against post-percutaneous coronary intervention microvascular dysfunction, ischemia, and inflammation among antiplatelet and antithrombotic agents - The PROTECT-TIMI-30 Trial [J].
Gibson, C. Michael ;
Morrow, David A. ;
Murphy, Sabina A. ;
Palabrica, Theresa M. ;
Jennings, Lisa K. ;
Stone, Peter H. ;
Lui, Henry H. ;
Bulle, Thomas ;
Lakkis, Nasser ;
Kovach, Richard ;
Cohen, David J. ;
Fish, Polly ;
McCabe, Carolyn H. ;
Braunwald, Eugene .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (12) :2364-2373
[8]   Elevations in cardiac troponin measurements: False false-positivesThe real truth [J].
Allan S. Jaffe .
Cardiovascular Toxicology, 2001, 1 (2) :87-92
[9]   Biomarkers in acute cardiac disease - The present and the future [J].
Jaffe, Allan S. ;
Babuin, Luciano ;
Apple, Fred S. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (01) :1-11
[10]   It's time for a change to a troponin standard [J].
Jaffe, AS ;
Ravkilde, J ;
Roberts, R ;
Naslund, U ;
Apple, FS ;
Galvani, M ;
Katus, H .
CIRCULATION, 2000, 102 (11) :1216-1220