Rotary Ni-Ti profile systems for preparing curved canals in resin blocks: influence of operator on instrument breakage

被引:89
作者
Mandel, E
Adib-Yazdi, M
Benhamou, LM
Lachkar, T
Mesgouez, C
Sobel, M
机构
[1] Univ Paris 07, Sch Dent, Endodont Dept, F-75006 Paris, France
[2] Univ Montpellier, Sch Dent, Endodont Dept, Montpellier, France
关键词
instrument fracture; Nickel-Titanium; root canal preparation; rotary files; simulated canals;
D O I
10.1046/j.1365-2591.1999.00239.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim The aim of this study was to determine the incidence of fracture of ProFile 0.4 and 0.6 taper Series 29 nickel-titanium instruments with respect to operator experience, Methodology A total of 125 simulated root canals in resin blocks with the same geometrical shape in terms of angle and radius of curvature and coronal and apical orifice diameter were used. Five operators prepared all the specimens using an identical step-down instrument sequence, each one preparing 25 canals. The operators included two endodontists and three general practitioners. Statistical data concerning the incidence of instrument failure was compiled using Statlab and Fisher's partial least square difference analysis of variance. Results A total of 21 (16.8%) Instruments fractured, all had 0.04 tapers. Nine size 25 instruments failed, 9 size 20 instruments failed and 3 size 15. During the study, the Binary Tree analysis of instrument failure revealed two operator populations belonging to two different study periods. The first period. which represented the first 13 root canal preparations, was called the 'learning period', and the second period. which represented the next 12 sample preparations, was called the 'application period'. A greater number of instruments failed during the first period than during the second. In the 'learning period', both groups of operators learned the same way. In the 'application period'. two groups could be distinguished; the first group consisted of a general practitioner who produced worse results, and the second group consisted of the other four operators. Conclusions The results indicate the necessity of mastering this rotary canal preparation technique, and the importance of improving competence through learning and experience.
引用
收藏
页码:436 / 443
页数:8
相关论文
共 23 条
[1]   Comparison of two stainless steel files to shape simulated root canals [J].
AlOmari, MAO ;
Bryant, S ;
Dummer, PMH .
INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) :35-45
[2]   A comparison of stainless steel Flexofiles and nickel-titanium NiTiFlex files during the shaping of simulated canals [J].
Bishop, K ;
Dummer, PMH .
INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) :25-34
[3]  
DAGHER FEB, 1995, J ENDODONT, V21, P264
[4]   A COMPARISON OF CANAL PREPARATION WITH NICKEL-TITANIUM AND STAINLESS-STEEL INSTRUMENTS [J].
ESPOSITO, PT ;
CUNNINGHAM, CJ .
JOURNAL OF ENDODONTICS, 1995, 21 (04) :173-176
[5]   THE DOUBLE-FLARED TECHNIQUE - AN ALTERNATIVE FOR BIOMECHANICAL PREPARATION [J].
FAVA, LRG .
JOURNAL OF ENDODONTICS, 1983, 9 (02) :76-80
[6]   A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS [J].
GLOSSON, CR ;
HALLER, RH ;
DOVE, SB ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1995, 21 (03) :146-151
[7]  
KAVANAGH D, 1998, ENDODONTICS DENT TRA, V14, P1620
[8]   THE RISK OF PERFORATION IN THE CURVED CANAL - ANTICURVATURE FILING COMPARED WITH THE STEPBACK TECHNIQUE [J].
LIM, SS ;
STOCK, CJR .
INTERNATIONAL ENDODONTIC JOURNAL, 1987, 20 (01) :33-39
[9]  
LUITEN DJ, 1995, J ENDODONT, V13, P215
[10]  
MARTIN G, 1997, J ENDODONT, V16, P554