Screw fixation of the upper cervical spine in the pediatric population Clinical article

被引:63
作者
Haque, Atif [1 ]
Price, Angela V. [2 ]
Sklar, Frederick H. [2 ]
Swift, Dale M. [2 ]
Weprin, Bradley E. [2 ]
Sacco, David J. [2 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Neurol Surg, Dallas, TX 75390 USA
[2] Neurosurg Childrens, Dallas, TX 75235 USA
关键词
occipitocervical fusion; atlantoaxial fusion; C-1 lateral mass screw; C-2 pars screw; C-2 laminar screw; C-2 nerve root sacrifice; ATLANTOAXIAL TRANSARTICULAR SCREW; VERTEBRAL ARTERY INJURY; C-1 LATERAL MASS; POLYAXIAL SCREW; TECHNICAL NOTE; CRANIOVERTEBRAL JUNCTION; ANATOMICAL SUITABILITY; FUSION; STABILIZATION; INSTABILITY;
D O I
10.3171/2009.2.PEDS08149
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Object. Rigid fixation of the upper cervical spine has become an established method of durable stabilization for a variety of craniocervical pathological entities in children. In children, specifically, the use of C1-2 transarticular screws has been proposed in recent literature to be the gold standard configuration for pathology involving these levels. The authors reviewed the use of rigid fixation techniques alternative to C1-2 transarticular screws in children. Factors evaluated included ease of placement, complications, and postoperative stability. Methods. Seventeen patients, ranging in age from 3 to 17 years (mean 9.6 years), underwent screw fixation involving the atlas or axis for a multitude of pathologies, including os odontoideum, Down syndrome, congenital instability, iatrogenic instability, or posttraumatic instability. All patients had preoperative instability of the occipitocervical or atlantoaxial spine demonstrated on dynamic lateral cervical spine radiographs. All patients also underwent preoperative CT scanning and MR imaging to evaluate the anatomical feasibility of the selected hardware placement. Thirteen patients underwent C1-2 fusion, and 4 underwent occipitocervical fusion, all incorporating C-1 lateral mass screws, C-2 pars screws, and/or C-2 laminar screws within their constructs. Patients who underwent occipitocervical fusion had no instrumentation placed at C-1. One patient's construct included sublaminar wiring at C-2. All patients received autograft onlay either from from rib (in 15 patients), split-thickness skull (1 patient), or local bone harvested within the operative field (1 patient). Nine patients' constructs were supplemented with recombinant human bone morphogenetic protein at the discretion of the attending physician. Eight patients had surgical sacrifice of 1 or both C-2 nerve roots to better facilitate visualization of the C-1 lateral mass. One patient was placed in halo-vest orthosis postoperatively, while the rest were maintained in rigid collars. Results. All 17 patients underwent immediate postoperative CT scanning to evaluate hardware placement. Follow-up was achieved in 16 cases, ranging from 2 to 39 months (mean 14 months), and repeated dynamic lateral cervical spine radiography was performed in these patients at the end of their follow-up period. Some, but not all patients, also underwent delayed postoperative CT scans, which were done at the discretion of the treating attending physician. No neurovascular injuries were encountered, no hardware revisions were required, and no infections were seen. No postoperative pain was seen in patients who underwent C-2 nerve root sacrifice. Stability was achieved in all patients postoperatively. In all patients who underwent delayed postoperative CT scanning, the presence of bridging bone was shown spanning the fused levels. Conclusions. Screw fixation of the atlas using lateral mass screws, in conjunction with C-2 root sacrifice in selected cases, and of the axis using pars or laminar screws is a safe method for achieving rigid fixation of the upper cervical spine in the pediatric population. (DOI: 10.3171/2009.2.PEDS08149)
引用
收藏
页码:529 / 533
页数:5
相关论文
共 33 条
[1]
Selection of a rigid internal fixation construct for stabilization at the craniovertebral junction in pediatric patients [J].
Anderson, Richard C. E. ;
Ragel, Brian T. ;
Mocco, J. ;
Bohman, Leif-Erik ;
Brockmeyer, Douglas L. .
JOURNAL OF NEUROSURGERY, 2007, 107 (01) :36-42
[2]
Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques [J].
Aryan, Henry E. ;
Iewman, C. Benjamin ;
Nottmeier, Eric W. ;
Acosta, Frank L., Jr. ;
Wang, Vincent Y. ;
Ames, Christopher P. .
JOURNAL OF NEUROSURGERY-SPINE, 2008, 8 (03) :222-229
[3]
Internal reduction established by occiput-C2 pedicle polyaxial screw stabilization in pediatric atlantoaxial rotatory fixation [J].
Belen, Deniz ;
Simsek, Serkan ;
Yigitkanli, Kazim ;
Bavbek, Murad .
PEDIATRIC NEUROSURGERY, 2006, 42 (05) :328-332
[4]
A comprehensive review of the safety profile of bone morphogenetic protein in spine surgery [J].
Benglis, David ;
Wang, Michael Y. ;
Levi, Allan D. .
NEUROSURGERY, 2008, 62 (05) :423-431
[5]
PEDIATRIC CERVICAL-SPINE INSTRUMENTATION USING SCREW FIXATION [J].
BROCKMEYER, D ;
APFELBAUM, R ;
TIPPETS, R ;
WALKER, M ;
CAREY, L .
PEDIATRIC NEUROSURGERY, 1995, 22 (03) :147-157
[6]
Anatomical suitability of C1-2 transarticular screw placement in pediatric patient [J].
Brockmeyer, DL ;
York, JE ;
Apfelbaum, RI .
JOURNAL OF NEUROSURGERY, 2000, 92 (01) :7-11
[7]
Brockmeyer DL, 2007, J NEUROSURG, V107, P173, DOI 10.3171/PED-07/08/173
[8]
Relationship of the internal carotid artery to the anterior aspect of the C1 vertebra [J].
Currier, Bradford L. ;
Maus, Tim P. ;
Eck, Jason C. ;
Larson, Dirk R. ;
Yaszemski, Michael J. .
SPINE, 2008, 33 (06) :635-639
[9]
Quantitative anatomy of the lateral mass of the atlas [J].
Dong, Y ;
Hong, MX ;
Li, JY ;
Lin, MY .
SPINE, 2003, 28 (09) :860-863
[10]
Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 67 pediatric patients [J].
Gluf, WM ;
Brockmeyer, DL .
JOURNAL OF NEUROSURGERY-SPINE, 2005, 2 (02) :164-169