Generation of dynamic temporal and spatial concentration gradients using microfluidic devices

被引:176
作者
Lin, F [1 ]
Saadi, W
Rhee, SW
Wang, SJ
Mittal, S
Jeon, NL
机构
[1] Univ Calif Irvine, Dept Phys & Astron, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
关键词
D O I
10.1039/b313600k
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes a microfluidic approach to generate dynamic temporal and spatial concentration gradients using a single microfluidic device. Compared to a previously described method that produced a single fixed gradient shape for each device, this approach combines a simple "mixer module" with gradient generating network to control and manipulate a number of different gradient shapes. The gradient profile is determined by the configuration of fluidic inputs as well as the design of microchannel network. By controlling the relative flow rates of the fluidic inputs using separate syringe pumps, the resulting composition of the inlets that feed the gradient generator can be dynamically controlled to generate temporal and spatial gradients. To demonstrate the concept and illustrate this approach, examples of devices that generate ( 1) temporal gradients of homogeneous concentrations, ( 2) linear gradients with dynamically controlled slope, baseline, and direction, and (3) nonlinear gradients with controlled nonlinearity are shown and their limitations are described.
引用
收藏
页码:164 / 167
页数:4
相关论文
共 14 条
[1]  
BEHAR TN, 1994, J NEUROSCI, V14, P29
[3]   Signal transduction - Signals to move cells [J].
Dekker, LV ;
Segal, AW .
SCIENCE, 2000, 287 (5455) :982-+
[4]   Generation of gradients having complex shapes using microfluidic networks [J].
Dertinger, SKW ;
Chiu, DT ;
Jeon, NL ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1240-1246
[5]   Generation of solution and surface gradients using microfluidic systems [J].
Jeon, NL ;
Dertinger, SKW ;
Chiu, DT ;
Choi, IS ;
Stroock, AD ;
Whitesides, GM .
LANGMUIR, 2000, 16 (22) :8311-8316
[6]   Neutrophil chemotaxis in linear and complex gradients of interleukin-8 formed in a microfabricated device [J].
Jeon, NL ;
Baskaran, H ;
Dertinger, SKW ;
Whitesides, GM ;
Van de Water, L ;
Toner, M .
NATURE BIOTECHNOLOGY, 2002, 20 (08) :826-830
[7]   A miniaturized, parallel, serially diluted immunoassay for analyzing multiple antigens [J].
Jiang, XY ;
Ng, JMK ;
Stroock, AD ;
Dertinger, SKW ;
Whitesides, GM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (18) :5294-5295
[8]   A fibrin or collagen gel assay for tissue cell chemotaxis: Assessment of fibroblast chemotaxis to GRGDSP [J].
Knapp, DM ;
Helou, EF ;
Tranquillo, RT .
EXPERIMENTAL CELL RESEARCH, 1999, 247 (02) :543-553
[9]  
NELSON RD, 1975, J IMMUNOL, V115, P1650
[10]   Chaotic mixer for microchannels [J].
Stroock, AD ;
Dertinger, SKW ;
Ajdari, A ;
Mezic, I ;
Stone, HA ;
Whitesides, GM .
SCIENCE, 2002, 295 (5555) :647-651