Comparison of two probe preparation methods using long oligonucleotide microarrays

被引:6
作者
Al-Mulla, F [1 ]
Al-Tamimi, R [1 ]
Bitar, MS [1 ]
机构
[1] Kuwait Univ, Fac Med, Dept Pathol, Mol Pathol Lab, Safat 13110, Kuwait
关键词
D O I
10.2144/04375RR03
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of oligonucleotides as a capture platform for microarray-based experiments is gaining popularity. Oligonucleotide-based microarrays involving various probe preparations have been compared by a number of researchers. Limited data are available, however regarding the concordances and efficacies of various probe preparations on long oligonucleotide-based microarrays. Accordingly, the current investigation assesses two labeling methods, namely Atlas(TM) PowerScrip(TM) fluorescent cDNA (random printing) and T7 in vitro transcription cRNA [poly(T)priming] labeling kits. Our data revealed that a high degree of reproducibility among the examined genes for each assay used with correlation coefficients of 0.93 and 0.94 for random printing and poly(T) printing, respectively. It is worthy of note, however that when the two assaying methods were compared, the data showed a poor correlation coefficient. A confirmatory step involving real-time reverse transcription PCR (RT-PCR) of 18 selected genes favors the superiority of the cDNA fluorescent labeling over the T7 labeling method. Overall, the microarray results generated by the poly(T) printing methodologly should be viewed cautiously even when high reproducibility is evident.
引用
收藏
页码:827 / 833
页数:7
相关论文
共 33 条
[1]  
Afshari CA, 1999, CANCER RES, V59, P4759
[2]   Science, medicine, and the future - DNA microarrays in medical practice [J].
Aitman, TJ .
BRITISH MEDICAL JOURNAL, 2001, 323 (7313) :611-615
[3]   The lymphochip: A specialized cDNA microarray for the genomic-scale analysis of gene expression in normal and malignant lymphocytes [J].
Alizadeh, A ;
Eisen, M ;
Davis, RE ;
Ma, C ;
Sabet, H ;
Tran, T ;
Powell, JI ;
Yang, L ;
Marti, GE ;
Moore, DT ;
Hudson, JR ;
Chan, WC ;
Greiner, T ;
Weisenburger, D ;
Armitage, JO ;
Lossos, I ;
Levy, R ;
Botstein, D ;
Brown, PO ;
Staudt, LM .
COLD SPRING HARBOR SYMPOSIA ON QUANTITATIVE BIOLOGY, 1999, 64 :71-78
[4]   Fidelity and reproducibility of antisense RNA amplification for the study of gene expression in human CD34+ haemopoietic stem and progenitor cells [J].
Attia, MA ;
Welsh, JP ;
Laing, K ;
Butcher, PD ;
Gibson, FM ;
Rutherford, TR .
BRITISH JOURNAL OF HAEMATOLOGY, 2003, 122 (03) :498-505
[5]   Sources of variability and effect of experimental approach on expression profiling data interpretation [J].
Bakay, M ;
Chen, YW ;
Borup, R ;
Zhao, P ;
Nagaraju, K ;
Hoffman, EP .
BMC BIOINFORMATICS, 2002, 3 (1)
[6]   Spotted long oligonucleotide arrays for human gene expression analysis [J].
Barczak, A ;
Rodriguez, MW ;
Hanspers, K ;
Koth, LL ;
Tai, YC ;
Bolstad, BM ;
Speed, TP ;
Erle, DJ .
GENOME RESEARCH, 2003, 13 (07) :1775-1785
[7]   ANALYSIS OF GENE-EXPRESSION IN SINGLE LIVE NEURONS [J].
EBERWINE, J ;
YEH, H ;
MIYASHIRO, K ;
CAO, YX ;
NAIR, S ;
FINNELL, R ;
ZETTEL, M ;
COLEMAN, P .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (07) :3010-3014
[8]   Advantages of mRNA amplification for microarray analysis [J].
Feldman, AL ;
Costouros, NG ;
Wang, E ;
Qian, M ;
Marincola, FM ;
Alexander, HR ;
Libutti, SK .
BIOTECHNIQUES, 2002, 33 (04) :906-+
[9]   cDNA array hybridization after laser-assisted microdissection from nonneoplastic tissue [J].
Fink, L ;
Kohlhoff, S ;
Stein, MM ;
Hänze, J ;
Weissmann, N ;
Rose, F ;
Akkayagil, E ;
Manz, D ;
Grimminger, F ;
Seeger, W ;
Bohle, RM .
AMERICAN JOURNAL OF PATHOLOGY, 2002, 160 (01) :81-90
[10]   Directly labeled mRNA produces highly precise and unbiased differential gene expression data [J].
Gupta, V ;
Cherkassky, A ;
Chatis, P ;
Joseph, R ;
Johnson, AL ;
Broadbent, J ;
Erickson, T ;
DiMeo, J .
NUCLEIC ACIDS RESEARCH, 2003, 31 (04) :e13