Long-term clinical follow-up after successful repeat percutaneous intervention for stent restenosis

被引:168
作者
Reimers, B [1 ]
Moussa, I [1 ]
Akiyama, T [1 ]
Tucci, G [1 ]
Ferraro, M [1 ]
Martini, G [1 ]
Blengino, S [1 ]
DiMario, C [1 ]
Colombo, A [1 ]
机构
[1] COLUMBUS CLIN, MILAN, ITALY
关键词
D O I
10.1016/S0735-1097(97)00142-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This study evaluated the long-term clinical outcome of successful repeat percutaneous intervention after in-stent restenosis. Background. Recurrence of symptoms and angiographic restenosis after stent implantation are observed in 15% to 35% of cases. Repeat percutaneous treatment for in-stent restenosis has been shown to be safe, with high immediate success, but little is known about the long-term clinical outcome. Methods. Clinical follow up (minimum 9 months) was obtained in a consecutive series of 124 patients (127 vessels) presenting with stent restenosis who were successfully treated with repeat percutaneous intervention. Results. Clinical follow-up was obtained in all 124 patients at a mean [+/-SD] of 27.4 +/- 14.7 months (range 9 to 66); a stress test was available in 88 patients (71%). Recurrence of clinical events occurred in 25 patients (20%) and included death from any cause in 2 patients (2%), target vessel revascularization in 14 (11%), myocardial infarction in 1 (1%) and positive stress test results or recurrence of symptoms (Canadian Cardiovascular Society class I to IV) treated medically in 8 (6%). Cumulative event-free survival at 12 and 24 months was 86.2% and 80.7%, respectively, Significant predictive factors of recurrence of clinical events were repeat intervention in saphenous vein grafts, multivessel disease, low ejection fraction and a less than or equal to 3 month interval between stent implantation and repeat intervention. Conclusions. In-stent balloon angioplasty for stent restenosis in native vessels seems to be an effective method in terms of a low long-term clinical event rate. (C) 1997 by the American College of Cardiology.
引用
收藏
页码:186 / 192
页数:7
相关论文
共 36 条
  • [1] MANAGEMENT OF RESTENOSIS WITHIN THE PALMAZ-SCHATZ CORONARY STENT (THE UNITED-STATES MULTICENTER EXPERIENCE)
    BAIM, DS
    LEVINE, MJ
    LEON, MB
    LEVINE, S
    ELLIS, SG
    SCHATZ, RA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (04) : 364 - 366
  • [2] ANTISENSE THERAPY FOR ANGIOPLASTY RESTENOSIS - SOME CRITICAL CONSIDERATIONS
    BENNETT, MR
    SCHWARTZ, SM
    [J]. CIRCULATION, 1995, 92 (07) : 1981 - 1993
  • [3] REPEAT CORONARY ANGIOPLASTY - CORRELATES OF A 2ND RESTENOSIS
    BLACK, AJR
    ANDERSON, HV
    ROUBIN, GS
    POWELSON, SW
    DOUGLAS, JS
    KING, SB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (04) : 714 - 718
  • [4] DISRUPTION OF A CORONARY STENT DURING ATHERECTOMY FOR RESTENOSIS
    BOWERMAN, RE
    PINKERTON, CA
    KIRK, B
    WALLER, BF
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1991, 24 (04): : 248 - 251
  • [5] INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE
    COLOMBO, A
    HALL, P
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    MARTINI, G
    GAGLIONE, A
    GOLDBERG, SL
    TOBIS, JM
    [J]. CIRCULATION, 1995, 91 (06) : 1676 - 1688
  • [6] BALLOON ANGIOPLASTY FOR THE TREATMENT OF LESIONS IN SAPHENOUS-VEIN BYPASS GRAFTS
    DEFEYTER, PIMJ
    VANSUYLEN, RJ
    DEJAEGERE, PPT
    TOPOL, EJ
    SERRUYS, PW
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (07) : 1539 - 1549
  • [7] SMALL STENT SIZE AND INTIMAL HYPERPLASIA CONTRIBUTE TO RESTENOSIS - A VOLUMETRIC INTRAVASCULAR ULTRASOUND ANALYSIS
    DUSSAILLANT, GR
    MINTZ, GS
    PICHARD, AD
    KENT, KM
    SATLER, LF
    POPMA, JJ
    WONG, SC
    LEON, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (03) : 720 - 724
  • [8] Stents for intracoronary placement: Current status and future directions
    Eeckhout, E
    Kappenberger, L
    Goy, JJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (04) : 757 - 765
  • [9] LONG-TERM ANGIOGRAPHIC AND CLINICAL OUTCOME AFTER IMPLANTATION OF BALLOON-EXPANDABLE STENTS IN AORTOCORONARY SAPHENOUS-VEIN GRAFTS
    FENTON, SH
    FISCHMAN, DL
    SAVAGE, MP
    SCHATZ, RA
    LEON, MB
    BAIM, DS
    KING, SB
    HEUSER, RR
    CURRY, RC
    RAKE, RC
    GOLDBERG, S
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (12) : 1187 - 1191
  • [10] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501