Analysis of methylamine by solid-phase microextraction and HPLC after on-fibre derivatization with 9-fluorenylmethyl chloroformate

被引:23
作者
Herráez-Hernández, R [1 ]
Cháfer-Pericás, C [1 ]
Campíns-Falcó, P [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Burjassot, Spain
关键词
methylamine; microextraction; HPLC;
D O I
10.1016/j.aca.2004.02.067
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the determination of methylamine (MA) in aqueous matrices is reported which uses solid-phase microextraction (SPME) for enrichment and derivatization of the analyte, and high performance liquid chromatography (HPLC). The fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC) has been used for derivatization. The SPME fibres were successively immersed in the samples and in the derivatization solutions to extract MA and FMOC, respectively. After a defined time of reaction, the derivatized analyte was desorbed into the chromatographic system, and chromatographed in a LiChrosphere 100 RP 18, 125 mm x 4 mm i.d., 5 mum, column under gradient elution. In order to improve the MA-FMOC peak profile, a precolumn (20 mm x 2.1 mm i.d., packed with Hypersil C-18 phase, 30 mum) was connected on-line to the analytical column by means of a switching valve. The experimental conditions (including fibre coating, times of adsorption, reaction and desorption, and concentration of reagent) have been optimised, and the results have been compared with those achieved by using a method previously validated for aliphatic amines in which extraction and derivatization were carried into C-18 solid-phase extraction (SPE) cartridges. Although less sensitive, the SPME based method allowed the quantification of MA over the range 2.5-10.0 mug/ml with linearity, reproducibility and accuracy comparable to that of the SPE based method, the limit of detection being 0.75 mug/ml. The main advantages of the proposed SPME procedure are: sample handling involved in the extraction and derivatization steps was considerably reduced, it was free organic solvent and non-destructive. Moreover, the proposed conditions allowed the selective determination of MA in the presence of other primary and secondary short-chain aliphatic amines. The utility of the proposed procedure for the quantification of MA in different types of waters is discussed. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:425 / 433
页数:9
相关论文
共 22 条
  • [1] Alpendurada MD, 2000, J CHROMATOGR A, V889, P3
  • [2] AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION
    ARTHUR, CL
    KILLAM, LM
    BUCHHOLZ, KD
    PAWLISZYN, J
    BERG, JR
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (17) : 1960 - 1966
  • [3] CAMPINS P, 2000, ENCY SEPARATION SCI, P743
  • [4] Derivatization of amines in solid-phase extraction supports with 4-fluorenylmethyl chloroformate for liquid chromatography
    CampinsFalco, P
    HerraezHernandez, R
    SevillanoCabeza, A
    Trumpler, I
    [J]. ANALYTICA CHIMICA ACTA, 1997, 344 (1-2) : 125 - 136
  • [5] A novel water-soluble fluorescent probe for the determination of methylamine
    Gu, H
    Ma, HM
    Liang, SC
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (04): : 570 - 573
  • [6] On-line derivatization into precolumns for the determination of drugs by liquid chromatography and column switching: Determination of amphetamines in urine
    HerraezHernandez, R
    CampinsFalco, P
    SevillanoCabeza, A
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (05) : 734 - 739
  • [7] On-fiber derivatization for direct immersion solid-phase microextraction. Part II. Acylation of amphetamine with pentafluorobenzoyl chloride for urine analysis
    Koster, EHM
    Bruins, CHP
    de Jong, GJ
    [J]. ANALYST, 2002, 127 (05) : 598 - 602
  • [8] Field sampling and determination of formaldehyde in indoor air with solid-phase microextraction and on-fiber derivatization
    Koziel, JA
    Noah, J
    Pawliszyn, J
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (07) : 1481 - 1486
  • [9] Determination of primary and secondary aliphatic amines by N-hydroxysuccinimidyl 4,3,2′-naphthapyrone-4-acetate and reversed-phase high-performance liquid chromatography
    Liu, X
    Wang, H
    Liang, SC
    Zhang, HS
    [J]. ANALYTICA CHIMICA ACTA, 2001, 441 (01) : 45 - 52
  • [10] Optimization of a derivatization-solid-phase microextraction method for the analysis of thirty phenolic pollutants in water samples
    Llompart, M
    Lourido, M
    Landín, P
    García-Jares, C
    Cela, R
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) : 137 - 148