Failure analysis-assisted FMEA

被引:42
作者
Cassanelli, G.
Mura, G.
Fantini, F.
Vanzi, M.
Plano, B.
机构
[1] Univ Modena, DII, I-41100 Modena, Italy
[2] Univ Cagliari, INFM, DIEE, I-09123 Cagliari, Italy
[3] Univ Bordeaux 1, IXL Lab, F-33405 Talence, France
关键词
D O I
10.1016/j.microrel.2006.07.072
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, ordinary FMEA (Failure Mode and Effects Analysis) was applied during the design phase of an electric motor control system for vehicle HVAC (HeatingNentilation/Air Conditioning). The analysis of the field data from the second year forces to review FMEA. The corrective actions, planned on the basis of the sole failure mode, as usual in FMEA, proved to be inadequate and Failure Analysis was performed to understand the failure mechanism of the indicted component and integrate. New proper corrective actions were devised and successfully implemented.
引用
收藏
页码:1795 / 1799
页数:5
相关论文
共 3 条
[1]  
*IEC, 60812 IEC
[2]  
MURA G, IN PRESS P IPFA P6 S
[3]  
VANZI M, 1995, P ISTFA SANT CLAR CA, P249