Hepatic artery: Variability in measurement of resistive index and systolic acceleration time in healthy volunteers

被引:37
作者
Paulson, EK
Kliewer, MA
Frederick, MG
Keogan, MT
Delong, DM
Nelson, RC
机构
[1] Department of Radiology, Duke University Medical Center, Durham, NC 27710, Erwin Rd
关键词
blood; flow dynamics; hepatic studies; liver; blood supply; ultrasound; (US); Doppler studies;
D O I
10.1148/radiology.200.3.8756922
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the intrinsic sampling variability of measurements of hepatic artery resistive index and systolic acceleration time in healthy subjects and to estimate the components of variability attributable to the sonographer, individual measurement, and subject. MATERIALS AND METHODS: In a randomized, controlled (blinded) fashion, nine sonographers measured hepatic artery resistive index and systolic acceleration time in five healthy subjects by using Doppler ultrasound (US). Analysis of variance was used to estimate the contribution of several factors to the observed variability in measurements. RESULTS: The standard deviation for a single measurement was 0.08 for resistive index and 39 msec for systolic acceleration time. For resistive index, the estimated variance components were 0.0012 (18%), 0.0004 (6%), and 0.0050 (76%) for the subject, sonographer, and intrinsic variability, respectively. For systolic acceleration time, the estimated variance components were 59 msec (4%), 264 msec (17%), and 1,250 msec (79%) for the subject, sonographer, and intrinsic variability, respectively. CONCLUSION: Because of substantial variability in hepatic arterial measures, caution is indicated when interpreting small changes in the measurement of these Doppler US indexes.
引用
收藏
页码:725 / 729
页数:5
相关论文
共 21 条
[1]   PORTA-HEPATIS - DUPLEX DOPPLER US WITH ANGIOGRAPHIC CORRELATION [J].
ALPERN, MB ;
RUBIN, JM ;
WILLIAMS, DM ;
CAPEK, P .
RADIOLOGY, 1987, 162 (01) :53-56
[2]   MEASUREMENT OF NORMAL PORTAL VENOUS-BLOOD FLOW BY DOPPLER ULTRASOUND [J].
BROWN, HS ;
HALLIWELL, M ;
QAMAR, M ;
READ, AE ;
EVANS, JM ;
WELLS, PNT .
GUT, 1989, 30 (04) :503-509
[3]   PULSUS TARDUS - ITS CAUSE AND POTENTIAL LIMITATIONS IN DETECTION OF ARTERIAL-STENOSIS [J].
BUDE, RO ;
RUBIN, JM ;
PLATT, JF ;
FECHNER, KP ;
ADLER, RS .
RADIOLOGY, 1994, 190 (03) :779-784
[4]   DOPPLER FLOWMETRY AND PORTAL-HYPERTENSION [J].
BURNS, P ;
TAYLOR, K ;
BLEI, AT .
GASTROENTEROLOGY, 1987, 92 (03) :824-826
[5]  
BURNS PN, 1985, RADIOL CLIN N AM, V23, P641
[6]   HEPATIC-ARTERY STENOSIS AND THROMBOSIS IN TRANSPLANT RECIPIENTS - DOPPLER DIAGNOSIS WITH RESISTIVE INDEX AND SYSTOLIC ACCELERATION TIME [J].
DODD, GD ;
MEMEL, DS ;
ZAJKO, AB ;
BARON, RL ;
SANTAGUIDA, LA .
RADIOLOGY, 1994, 192 (03) :657-661
[8]   NORMAL RENAL-ARTERY SPECTRAL DOPPLER WAVE-FORM - A CLOSER LOOK [J].
HALPERN, EJ ;
DEANE, CR ;
NEEDLEMAN, L ;
MERTON, DA ;
EAST, SA .
RADIOLOGY, 1995, 196 (03) :667-673
[9]   VENOOCCLUSIVE LIVER-DISEASE AFTER BONE-MARROW TRANSPLANTATION - FINDINGS AT DUPLEX SONOGRAPHY [J].
HERBETKO, J ;
GRIGG, AP ;
BUCKLEY, AR ;
PHILLIPS, GL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (05) :1001-1005
[10]   HEPATIC-ARTERY RESISTANCE BEFORE AND AFTER STANDARD IDEAL IN SUBJECTS WITH DISEASED AND HEALTHY LIVERS [J].
JOYNT, LK ;
PLATT, JF ;
RUBIN, JM ;
ELLIS, JH ;
BUDE, RO .
RADIOLOGY, 1995, 196 (02) :489-492