A randomized, controlled trial of transcutaneous carbon dioxide monitoring during ERCP

被引:56
作者
Nelson, DB
Freeman, ML
Silvis, SE
Cass, OW
Yakshe, PN
Vennes, J
Stahnke, LL
Herman, M
Hodges, J
机构
[1] Hennepin Cty Med Ctr, Dept Med GI, Minneapolis, MN 55415 USA
[2] Vet Adm Med Ctr, Minneapolis, MN 55417 USA
[3] Univ Minnesota, Minneapolis, MN USA
[4] Pk Nicollet Clin, St Louis Pk, MN USA
关键词
D O I
10.1016/S0016-5107(00)70357-9
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Pulse oximetry, used to monitor oxygen saturation during endoscopy, does not directly measure hypoventilation. Study goals were to determine whether transcutaneous carbon dioxide (PtcCO(2)) monitoring during endoscopic retrograde cholangiopancreatography (ERCP) prevents severe hypoventilation and to assess the accuracy of clinical observation and pulse oximetry in detecting hypoventilation. Methods: All patients received intensive clinical and electronic monitoring including pulse oximetry. Supplemental oxygen was administered for pulse oximetry < 90%. Patients were randomized to a treatment arm (group 1) where PtcCO(2) monitoring guided sedation or a control arm (group 2) where PtcCO(2) was recorded but unavailable for guiding sedation. Results: Group 1 had significantly fewer episodes of severe carbon dioxide retention (rise in PtcCO(2) greater than or equal to 40 mm Hg above baseline) than group 2 (0 of 199 versus 5 of 196, respectively p = 0.03), as well a shorter mean duration of procedure discomfort (8.3% of procedure duration rated as "uncomfortable" versus 11.5%, p = 0.04). Correlations between clinical observation and objective measures of ventilation were poor: level of sedation versus PtcCO(2) (R = 0.3) or pulse oximetry (R = 0.06); slowest respiratory rate versus PtcCO(2) (R = 0.4) or pulse oximetry (R = -0.4). PtcCO(2) rises of greater than 20 mm Hg occurred without oxygen desaturation in 10.7% of patients receiving supplemental oxygen. Conclusions: Carbon dioxide retention during ERCP is not reliably detected by clinical observation or by pulse oximetry in patients receiving supplemental oxygen. The addition of PtcCO(2) monitoring prevents severe carbon dioxide retention more effectively than intensive clinical monitoring and pulse oximetry alone. The clinical relevancy of this observation needs to be determined in an appropriately designed outcome study.
引用
收藏
页码:288 / 295
页数:8
相关论文
共 39 条
[1]
USE OF CAPNOGRAPHY AND TRANS-CUTANEOUS OXYGEN MONITORING DURING OUTPATIENT GENERAL-ANESTHESIA FOR ORAL-SURGERY [J].
ANDERSON, JA ;
CLARK, PJ ;
KAFER, ER .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1987, 45 (01) :3-10
[2]
[Anonymous], 1995, GASTROINTEST ENDOSC, V42, P626
[3]
RESULTS FROM THE AMERICAN SOCIETY FOR GASTROINTESTINAL ENDOSCOPY UNITED-STATES FOOD AND DRUG ADMINISTRATION COLLABORATIVE STUDY ON COMPLICATION RATES AND DRUG-USE DURING GASTROINTESTINAL ENDOSCOPY [J].
ARROWSMITH, JB ;
GERSTMAN, BB ;
FLEISCHER, DE ;
BENJAMIN, SB .
GASTROINTESTINAL ENDOSCOPY, 1991, 37 (04) :421-427
[4]
FREQUENT HYPOXEMIA AND APNEA AFTER SEDATION WITH MIDAZOLAM AND FENTANYL [J].
BAILEY, PL ;
PACE, NL ;
ASHBURN, MA ;
MOLL, JWB ;
EAST, KA ;
STANLEY, TH .
ANESTHESIOLOGY, 1990, 73 (05) :826-830
[5]
OXYGEN DESATURATION AND CHANGES IN BREATHING PATTERN IN PATIENTS UNDERGOING COLONOSCOPY AND GASTROSCOPY [J].
BARKIN, JS ;
KRIEGER, B ;
BLINDER, M ;
BOSCHBLINDER, L ;
GOLDBERG, RI ;
PHILLIPS, RS .
GASTROINTESTINAL ENDOSCOPY, 1989, 35 (06) :526-530
[6]
BELL GD, 1987, LANCET, V1, P1022
[7]
MONITORING AND SAFETY IN ENDOSCOPY [J].
BELL, GD .
BAILLIERES CLINICAL GASTROENTEROLOGY, 1991, 5 (01) :79-98
[8]
Capnography and ventilatory assessment during ambulatory dentoalveolar surgery [J].
Bennett, J ;
Petersen, T ;
Burleson, JA .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1997, 55 (09) :921-925
[9]
EFFECTS OF SUPPLEMENTAL OXYGEN ON CARDIAC-RHYTHM DURING UPPER GASTROINTESTINAL ENDOSCOPY - A RANDOMIZED CONTROLLED DOUBLE-BLIND TRIAL [J].
BOWLING, TE ;
HADJIMINAS, CL ;
POLSON, RJ ;
BARON, JH ;
FOALE, RA .
GUT, 1993, 34 (11) :1492-1497
[10]
VALUE OF CARBON DIOXIDE MONITORING DURING ANAESTHESIA [J].
BURTON, GW .
ANAESTHESIA, 1966, 21 (02) :173-+